10. TRANSMISSION ERROR EO1-11138
10-1
10. TRANSMISSION ERROR
When a terminal makes an inquiry but a communication error occurs for some reason and the inquiry to the other
station is not possible, the message “IRC CONNECT ERR” is displayed on that terminal and operation is
stopped.
When the Master Terminal cannot access the inquiring file because the Master Terminal is receiving DLL data,
the backup data is being updated between the Master and the Backup Master terminals, etc., the message
“MASTER IS BUSY” is displayed and operation is stopped.

10.1 Cause of Error

10.1.1 “IRC CONNECT ERR”

a) Communication with the other station is not possible due to a connection error (cable cut, Master
Terminal’s Power-OFF, etc.).
b) Comminication was made, but due to a text error, the other station cannot recognize it correctly.

10.1.2 “MASTER IS BUSY”

Cannot access the inquiring file due to the following causes:
a) The Master Terminal is receiving DLL data from the PC.
b) Programming operations are under way on the Master Terminal.
c) Backup data updating process is under way.

10.2 Error Display

IRC CONNECT ERR MASTER IS BUSY
10.1 Cause of Error
* REG * 02-06-1999 03:04 1 1CLKendi
P1S1
IRC CONNECT ERR 01
Terminal ID of the other station
0.00
TOTAL
0.00
DISP1 DISP2 DISP3 DISP4 DISP5
* REG * 02-06-1999 03:04 1 1CLKendi
P1S1
MASTER IS BUSY
0.00
TOTAL
0.00
DISP1 DISP2 DISP3 DISP4 DISP5
NOTE: Depressing the [C] key cancels the error status.