Indicators
There are three indicators which show the status of the projector. Check the following for information about the indicator lights. If there is anything wrong, turn the projector off and contact your dealer.
When the projector is in a normal state, ...
POWER | TEMP | LAMP | STATE | REMARK |
|
|
|
|
|
Orange |
|
| Standby mode. |
|
|
|
|
|
|
Flashing |
|
| The projector is powering up. | Cannot turn the projector off. |
orange |
|
| ||
|
|
|
| |
|
|
|
|
|
Green |
|
| The projector is under normal |
|
|
| operation. |
| |
|
|
|
| |
|
|
|
|
|
| Off | Off | (1) The projector needs 110 |
|
| seconds to cool down as it |
| ||
|
|
|
| |
|
|
| was abnormally shut down |
|
Flashing |
|
| without the normal cooling | Cannot turn the projector on. |
green |
|
| down process. Or | |
|
|
| ||
|
|
| (2) The projector needs to cool |
|
|
|
| for 110 seconds after the |
|
|
|
| power is turned off. |
|
|
|
|
|
|
When the projector is in an abnormal state, ...
POWER | TEMP | LAMP | STATE | REMARK | |
|
|
|
|
| |
|
|
| (1) The lamp has exceeded its | Solution: | |
Orange | Off | Red | usage life. Or | • Install a new lamp. | |
(2) The lamp is not properly | • Please contact your dealer | ||||
|
|
| |||
|
|
| attached or is damaged. | for assistance. | |
|
|
|
|
| |
|
|
| The dust filter is seriously clogged | Solution: | |
Orange | Red | Off | with dust. The projector is going to | • Install a new filter. | |
|
|
| shut down. |
| |
|
|
|
| Solution: | |
|
|
| The internal temperature is too | • Make sure that the | |
|
|
| ventilation holes are not | ||
|
|
| high. | ||
|
|
| blocked. | ||
|
|
| • The intake ventilation or the | ||
|
|
| • Relocate the projector. | ||
Orange | Red | Off | exhaust ventilation is blocked. | ||
• The projector may be in a | • Stop using the projector until | ||||
|
|
| the ambient temperature | ||
|
|
| poorly ventilated location. | ||
|
|
| falls within the specified | ||
|
|
| • The ambient temperature | ||
|
|
| range. The maximum | ||
|
|
| may be too high. | ||
|
|
| operating temperature is | ||
|
|
|
| ||
|
|
|
| specified as 40°C / 104°F. | |
|
|
|
|
| |
|
|
|
| Solution: | |
|
|
|
| • Check if the power supply is | |
Orange | Flashing | Flashing | The fans are not working. | stable. | |
red | red | • Check if there is object stuck | |||
|
| ||||
|
|
|
| in the fans. | |
|
|
|
| • Contact your dealer. | |
|
|
|
|
|
32 Additional information