General Information

Model Number Description

All products are identified by a multiple character model number listed on the unit nameplate. An explanation of the alphanumeric identification code is provided below. Its use can define the unit's specific components, type of applica- tion, i.e. CV or VAV, for a particular unit.

When ordering replacement parts or requesting service, be sure to refer to the specific model number, serial number, and DL number (if applicable) stamped on the unit name- plate.

Sample Model No.:

S X H F - C20 4 0

A

1 0

A

1

5

B

1

D

0

1

A,R,L,etc.

Digit No.:

1 2 3 4 5,6,7 8 9

10

11 12

13

14

15

16

17

18

19

20

21+

Digit 1 - Unit Type

S = Self-Contained

Digit 2 - Unit Function

A = DX Cooling, No Heat

E = DX Cooling, Electric Heat

F = DX Cooling, Natural Gas Heat L = DX Cooling, Hot Water Heat S = DX Cooling, Steam Heat

X = DX Cooling, Extended Casings

# = DX Cooling, Propane Gas Heat

Digit 3 - Unit Airflow

H = Single-Zone

Digit 4 - Development Sequence

F= Sixth

Digits 5, 6, 7 - Nominal Capacity

C20 = 20 Tons

C55 = 55 Tons

C25 = 25 Tons

C60 = 60 Tons

C30 = 30 Tons

C70 = 70 Tons

C40 = 40 Tons

C75 = 75 Tons

C50 = 50 Tons

 

Digit 8 - Power Supply

4 = 460/60/3 XL

5 = 575/60/3 XL E = 200/60/3 XL F = 230/60/3 XL

Note: SEHF units (unit with electric heat) utilizing 208V or 230V require dual power source.

Digit 9 - Heating Capacity

Note: When the second digit calls for "F" (Gas Heat), the following values apply: Additionally, please note G and M available ONLY on 50 Ton models and above.

H = High Heat - 2 Stage

L = Low Heat - 2 Stage 0 = No Heat

J = Limited Modulating High Heat G = Limited Modulating Low Heat

P = Full Modulating High Heat M = Full Modulating Low Heat

Note: When the second digit

calls for "E" (electric heat), the following values apply:

D = 30 KW

R = 130 KW

H = 50 KW

U = 150 KW

L = 70 KW

V = 170 KW

N = 90 KW

W = 190 KW

Q = 110 KW

 

Note: When the second digit calls "L" (Hot Water) or "S" (Steam) Heat, one of the following valve size values must be in Digit 9: High Heat Coil: 1 = 50", 2 = .75",

3 = 1", 4 = 1.25", 5 = 1.5", 6 = 2". Low Heat Coil: A = .50", B = .75", C = 1", D = 1.25", E = 1.5", F = 2".

Digit 10 - Design Sequence 3 = Disconnect Redesign

Note: Sequence may be any letter A thru Z, or any digit 1 thru 9.

Digit 11 - Exhaust Option

0 = None

1 = Barometric

2 = 100% - 1.5 HP*

3 = 100% - 3 HP*

4 = 100% - 5 HP*

5 = 100% - 7.5 HP*

6 = 100% - 10 HP*

7 = 100% - 15 HP*

8 = 100% - 20 HP* A = 50% - 1.5 HP B = 50% - 3 HP C = 50% - 5 HP D = 50% - 7.5 HP

E = 100% - 1.5 HP** F = 100% - 3 HP** G = 100% - 5 HP** H = 100% - 7.5 HP** J = 100% - 10 HP** K = 100% - 15 HP** L = 100% - 20 HP**

#= 50% w/ Statitrac

*w/Statitrac

**w/o Statitrac (CV only)

Digit 12 - Exhaust Fan Drive

0

= None

8 = 800 PRM

4

= 400 RPM

9 = 900 RPM

5

= 500 RPM

A = 1000 RPM

6

= 600 RPM

B = 1100 RPM

7

= 700 RPM

 

Digit 13 - Filter Type

A = Throwaway

B = Cleanable Wire Mesh

C= High-Efficiency Throwaway

D= Bag with Prefilters

E= Cartridge with Prefilters

F= No Filters (T/A Rack Only)

G= No Filters (Bag/Cart. Rack Only)

Digit 14 - Supply Fan Horsepower

1

= 3.0 HP

6

= 20.0

HP

2

= 5.0 HP

7

= 25.0

HP

3

= 7.5 HP

8

= 30.0

HP

4

= 10.0 HP

9

= 40.0

HP1

5

= 15.0 HP

 

 

 

Digit 15 - Supply Fan Drive

5

= 500 RPM

 

B = 1100 RPM

6

= 600 RPM

 

C = 1200 RPM

7

= 700 RPM

 

D = 1300 RPM

8

= 800 RPM

 

E = 1400 RPM

9

= 900 RPM

 

F = 1500 RPM

A = 1000 RPM

G = 1600 RPM

Digit 16 - Fresh Air Section

A = No Fresh Air

B = 0-25% Manual

D = 0-100% Economizer

Digit 17 - System Control

1 = CV Control (Zone Control)

2= VAV-(S/A Temp Control without Inlet Guide Vanes)

3= VAV-(S/A Temp Control with Inlet Guide Vanes)

4= Space Pressure Control with Exhaust VFD without Bypass

5= Space Pressure Control with Exhaust VFD and Bypass

6= VAV Supply Air Temperature Control

with VFD w/o Bypass

7 = VAV Supply Air Temperature Control with VFD and Bypass

8 = Supply and Exhaust Fan with VFD without Bypass

9 = Supply and Exhaust Fan with VFD and Bypass

Digit 18 - Accessory Panel

0 = None

A = BAYSENS008* B = BAYSENS010* C = BAYSENS013* D = BAYSENS014* E = BAYSENS019* F = BAYSENS020* G = BAYSENS021*

Digit 19 - Ambient Control

0 = Standard

1 = 0 Degree Fahrenheit

Digit 20 - Agency Approval

0 = None (UL Gas Heater, see note)

1 = UL

2 = CSA

Note: Includes UL clsssified gas heating section only when second digit of Model No. is a "F".

Digits 21 - 38 - Miscellaneous

21A = Unit Disconnect Switch

22B = Hot Gas Bypass

23C = Economizer Control w/Comparative

Enthalpy

23 Z = Economizer Control w/Reference Enthalpy

23W = Economizer Control w/Dry Bulb

23O = None W/O Economizer

24E = Low Leak Fresh Air Dampers

25F = High Duct Temperature Thermostat

26G = High Capacity Evaporator Coil

27H = Copper Fins (Cond. only)

28K = Generic B.A.S. Module

29L = High-Efficiency Motors (Supply & Exhaust)

30M = Remote Human Interface

31N = Ventilation Override Module

32R = Extended Grease Lines

33T = Access Doors

34V = Interprocessor Communications Bridge

350 = No communication module

35Y = Trane Communication Interface Module

357 = LonTalk® Communication Interface Module

368 = Spring Isolators

376 = Factory-Powered 15A GFI Convenience Outlet

380 = None

1. Available as standard 460 volt only for 70 and 75 ton models.

4

Page 4
Image 4
Trane RT-SVX10C-EN specifications General Information, Model Number Description