CIR DOWN:

Committed Information Rate from AP to SU. Minimum downstream data rate (measured in

 

Kbps) at which the AP will attempt to deliver bandwidth to this SU. Maximum setting is

 

3000.

MIR UP:

Maximum Information Rate from SU to AP. Maximum upstream data rate (measured in

 

Kbps) at which the SU will attempt to deliver bandwidth to the AP. Maximum setting is

 

3000.

MIR UP:

Maximum Information Rate from AP to SU. Maximum data rate (measured in Kbps) at

 

which the AP will attempt to deliver bandwidth to this SU. Maximum setting is 3000.

DEVICE ID:

MAC address of the SU.

Creating an SU in the SU Database.

1.Connect to the AP (see Getting Started) and open the Subscriber Database page.

2.Enter SU ID (range 1 – 126).

3.Select either PRIORITY or REGULAR.

4.If SU will be part of an SU to SU group, enter the SU to SU group number.

5.CIR up: (SU to AP Committed Information Rate) – minimum upstream bandwidth for the SU in Kbps.