![](/images/new-backgrounds/1093051/9305165x1.webp)
NOTE: If the update is unsuccessful, the display will remain off and the oven will beep one long, low tone. If this occurs, repeat the above procedure. If the update fails multiple times, a smart card may be damaged. Please note that the oven will be inoperable until a successful update is performed. As such, TurboChef reinforces proper handling of smart cards to help prevent static damage, and recommends that each service technician keep a backup copy.
Test Mode
The TEST MODE serves the following purposes:
-To test individual oven components.
-To view oven information.
-To reset oven parameters.
-To input a new serial number.
To access the TEST MODE,
1. Press the up key from the OVEN OFF or
COOLING DOWN MODE to access the
CONFIG MODE.
2.Press the R3 soft key (Figure 12, page 15).
3.Input the password 2 4 3 3 (Figure 23).
The TEST MODE consists of two screens (Figures 21 and 22). Use the up and down keys to navigate between them.
From screen 1 of the TEST MODE, the user can:
L1 | INFO |
R1 | |
SERIAL_NUMBER | RUN: 65432 HR |
EC=82F 208V | IDLE: 12345 HR |
L2 | R2 |
FIRMWARE VERSION | |
L3 | R3 |
|
|
Figure 20: Info Screen
L1 | HEAT CTRL |
|
| TOP AIR | R1 | |
L2 | TEST PAGE 1 |
| R2 | |||
BELT CTRL |
|
| BOT AIR | |||
L3 | D EC27 450F | 45% | 100% | 23.9V | 0.0V | R3 |
|
|
|
|
|
|
|
From screen 2 of the TEST MODE, the user can:
-Input a new serial number
-Initiate a
-Erase oven settings and fault counts
-Change the maximum temperature from 550ºF to 600ºF, or vice versa.
NOTE: DO NOT change this setting unless instructed by TurboChef.
- Enable/disable maintenance mode*
*The maintenance mode will show temperature, heater operation, and other diagnostics while the oven is running.
Accessing the Heat Control Screen
From screen 1 of the TEST MODE (Figure 21), press L1 to access the heat control screen (Figure 24).
NOTE: This mode is intended for setting gas pressures on other TurboChef conveyor ovens. Even though the HhC 2020 is electric, this mode can be used to energize the heaters to verify proper operation and readings.
-Press L1 to turn the heaters on.
-Press R1 to turn the heaters off.
L1 | INPUT SN |
| MAX TEMP 550 | R1 | ||
L2 | TEST PAGE 2 |
| R2 | |||
|
| MAINT ON | ||||
L3 | ERASE/CLEAR |
|
|
|
| R3 |
|
|
|
|
| ||
Figure 22: Test Mode Screen 2 |
|
|
|
| ||
|
|
|
|
|
|
|
L1 | 1 |
|
|
| 4 | R1 |
| ENTER PASSWORD |
|
|
| ||
L2 | 2 | <2433> |
| 5 | R2 | |
|
|
| ||||
L3 | 3 |
|
|
| 6 | R3 |
|
|
|
|
| ||
Figure 23: Password Screen |
|
|
|
| ||
L1 | BURN FULL (LIGHT) |
| BURN OFF | R1 | ||
L2 | HEAT CTRL |
|
| R2 | ||
BURN LOW | TCC = 475F |
|
| |||
L3 | D EC27 450F | 45% | 100% | 23.9V | 0.0V | R3 |
1 7