3 2 T RO U B L E S H O OT I N G
Troubleshooting:
F7: RTD FAULT
Replace the RTD |
|
|
|
|
| YES | |
(page |
|
| |
|
|
| |
|
|
| |
|
|
|
|
Open the right end bell.
Is the RTD damaged or defective (page 22)?
NO
Is the RTD connected properly to the I/O control board (pages
NO
YES
Is the RTD open? Using an ohmmeter, measure at the control board (pages 37- 40). RTD should measure approximately 100 W at 32°F (0°C) See page 22 for ohm/temperature chart.
|
|
|
|
|
|
|
|
| YES |
|
| Correct wiring | |
|
|
|
| (pages | ||
|
|
|
|
| ||
|
|
|
|
| ||
|
|
|
|
|
|
|
Replace the I/O NO control board
(page A-8).
Troubleshooting:
F8: HIGH LIMIT TRIPPED
YES
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Are all the contacts |
Is the high limit thermostat |
|
|
| ||||
|
|
|
| closed on the high | |||
| NO |
|
| ||||
tripped (page 21)? |
|
|
| ||||
|
|
|
| limit thermostat? | |||
|
|
|
| ||||
|
|
|
|
|
|
| |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
Reset and determine why it tripped - over temp, blower failure, etc.
Check if the high limit probe or RTD is damaged or defec- tive, replace if needed (page
YES
Replace the I/O control board (page
Is the wiring correct (pages
37-40)?
NO
Correct wiring (pages
YES NO
Replace the high limit thermostat (page