Inspecting the Venting System

Vermont Castings, Majestic Products DVRT36/39/43

3/8" - 1/2"

 

SIT Pilot

 

PSE Pilot

 

3/8"-1/2"

 

Electronic

 

Ignition

 

F584-703/

 

FP1370

Fig. 48

Correct pilot flame appearance.

Glowing Lava Rock

LG231

Fig. 51 Correct burner flame appearance for DVRT43.

NOTE: Glowing lava rock for DVRT36, DVRT39 and DVRT43 is only allowed to be positioned at the front area (radiant portion) of the burner housing assembly.

5 Separate flames

Glowing Lava Rock

LG229

Fig. 49 Correct burner flame appearance for DVRT36.

5 Flame areas

Inspecting the Venting System

This appliance venting system is designed and constructed to develop a positive flow adequate to remove flue gases to the outside atmosphere.

Any foreign objects in the venting system, except those designed specifically for the venting system, may cause spillage of flue gases.

To inspect the venting system, make sure the main gas valve is off. Remove the window frame assembly. (Refer to Window Frame Assembly Removal section.) Using a flashlight, check the area above the baffle in the combustion dome. Clean if necessary.

Glowing Lava Rock

LG230

Fig. 50 Correct burner flame appearance for DVRT39.

28

10002428

Page 28
Image 28
Vermont Casting DVRT43 manual Inspecting the Venting System, Vermont Castings, Majestic Products DVRT36/39/43, 10002428