Vermont Casting DVRT39, DVRT43, DVRT36 manual Troubleshooting - Honeywell VS8421, 10002428

Models: DVRT39 DVRT36 DVRT43

1 50
Download 50 pages 26.47 Kb
Page 35
Image 35
Troubleshooting – Honeywell VS8421

Vermont Castings, Majestic Products DVRT36/39/43

Troubleshooting – Honeywell VS8421

START

Gas Supply On

YES

Remove the Window Frame Assembly before service work.

CHECK

 

 

Supply Line Hooked Up

NO

 

 

Shutoff Valve Open

 

 

 

 

 

 

Pilot Lights With Piezo Ignitor

YES

Pilot Stays Lit

YES

Pilot Lights Main Burner

YES

SYSTEM OK

 

 

 

 

Lockout Has Engaged. Wait 60

 

 

 

 

 

Seconds And Try Again.

 

 

 

For Spark At Electrode While

 

 

 

 

Depressing Piezo

 

NO

 

 

 

 

 

1/8" Gap To Pilot Hood Needed.

 

 

 

 

 

 

 

 

All Wiring Connections

 

 

 

 

Replace Piezo Ignitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Air In The Lines

 

 

 

 

Thermopile Needs A Min.

 

 

 

 

 

325mv. Adjust Pilot Flame

 

 

 

 

 

Height.

 

 

 

All Wiring Connections

 

NO

 

 

 

Replace Thermopile

 

 

 

 

Thermocouple Needs A Min. Of

 

 

 

 

 

14mv

 

 

 

 

Defective Valve. Turn To Pilot,

 

 

 

 

 

Meter Should Read Greater

 

 

 

 

 

Than 100mv. If Not, Replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valve Is Turned On

 

 

 

 

Wall Switch Is Not Turned On.

 

NO

 

Watch For Grounded Wires!

 

 

 

 

Thermopile Needs A Min. 325mv.

 

 

 

 

 

 

 

 

Plugged Burner Orifice

 

 

 

 

 

 

10002428

35

Page 35
Image 35
Vermont Casting DVRT39 Troubleshooting - Honeywell VS8421, Vermont Castings, Majestic Products DVRT36/39/43, 10002428