Optional Accessories

Vermont Castings, Majestic Products DVRT36/39/43

Optional Accessories

Fan Kits

FK-12 Fan Assembly

1.Open lower louvre.

2.Install FK-12 fan in back of unit between hearth supports. (Fig. 57)

3.Secure fan on Velcro strips.

4.Power to the fan can be supplied by plugging the supply lead into a conveniently located wall socket or by using a hard-wired EB-1 connector box.

5.Be sure fan motor does not touch nearby metal.

Side View

Cold Air

 

Box

Front of

Unit

Hearth Pan

Base Pan

FK-12 Fan

 

 

FP1004

Fig. 57 FK-12 Fan Kit placement.

FK-24 Fan Assembly

Fan specifications: 120 Volt, 60 Hz 75 Amp.

This fan does not require regular maintenance, however periodic cleaning is required. Check the area under the control door and in front of the fan and wipe or vacuum at least once a month during the operating season.

Should this fan require servicing, the power supply must be disconnected.

The FK-24 comes with the electrical cord attached.

1.Slide fan assembly from the left side into the fireplace opening, line up mounting holes with screw studs on back of fireplace and fasten with #10-24 hex nuts.

2.Install thermal sensor on bottom of firebox using #10-24 hex nuts.

3.Option A: Place electronic fan speed control box on bottom of fireplace base, lining up mounting holes with screw studs. Fasten fan speed control box with #10-24 hex nuts.

Option B: The speed control can be installed in an electrical box at normal wall switch height for convenient access.

4.The power supply may be connected in 2 ways:

10002428

Method A: Route the 6’ (1.8m) lead fitted to the unit to a conveniently located wall socket. Method B: If the EB-1 receptacle box (Part # ZA1200) was correctly connected when the unit was installed, the fan lead can be directly plugged into the EB-1 plug socket.

5.Whether wiring directly to the fan junction box (Option A) or into the EB-1 (electrical receptacle box, Option B), first ensure cable is secured using box connector.

The fireplace when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code. For USA installations, follow local codes and the National Electrical Code, ANSI/ NFPA No. 70.

Hard (Direct) Wire Hookup

First connect ground wire to ground stud located on the base of either box. Black wire from supply should connect to the variable speed switch. Alternate speed switch wire connects to temperature sensor. Alternate lead from sensor connects to fan. Alternate fan lead connects back to the white supply wire. (Fig. 59)

Any electrical rewiring of this fan must be completed by a qualified electrician.

Turn off all power before hookup.

 

Electrical

Heat

 

 

 

Box

sensor

 

 

 

 

Fan

 

 

 

F

P

 

 

 

TO

 

 

 

Fan Speed

Gas Line

Valve

 

Switch

 

 

FP1026

Fig. 58

FK-24 fan placement.

 

 

 

Temperature

 

Fan

 

 

 

 

sensor

 

 

Speed control

 

 

 

Black

 

 

 

White

 

 

 

Ground

 

 

 

 

 

 

 

FP1025

Fig. 59

FK-24 fan wiring.

 

 

 

 

 

 

 

43