Vermont Casting DVRT43, DVRT36, DVRT39 manual Clearance to Combustibles, Mantels, Hearth, 10002428

Models: DVRT39 DVRT36 DVRT43

1 50
Download 50 pages 26.47 Kb
Page 6
Image 6
Clearance to Combustibles

Vermont Castings, Majestic Products DVRT36/39/43

Clearance to Combustibles

Appliance

 

Top

0” (0mm)

Bottom

0” (0mm)

Side

0” (0mm)

Back

0” (0mm)

Venting

 

Concentric sections of DV Vent

1” (25mm)

Non-concentric sections of DV Vent

 

Sides and bottom

1” (25mm)

Top

2” (51mm)

Mantels

The height a combustible mantel is fitted above the fireplace is dependent on the depth of the mantel. This also applies to the distance between the mantel leg (if fitted) and the fireplace.

Refer to Figures 4a and 4b and the Mantel Charts below them for correct mounting heights and widths.

The distances and reference points are not affected by the fitting of a bay window front trim kit.

Noncombustible mantels and legs may be installed at any height and width around the appliance.

When using paint or lacquer to finish the mantel, it must be heat-resistant to prevent discoloration.

 

 

 

J

I

H

Black

 

 

 

Surround

 

 

 

G

 

 

 

F

Face

 

Mantel

 

 

 

 

Leg

 

 

 

 

Mantel

 

 

 

 

Leg

 

 

 

 

 

 

 

 

CFM164a

 

 

 

 

K

 

Side of

 

M

L

 

 

 

 

Combustion Chamber

N

 

 

 

 

 

O

 

 

 

 

 

 

 

CFM170

 

Mantel

 

Mantel Leg from Side

Ref.

Leg Depth

Ref.

of Comb. Opening

V

W

X

Y

Z

A B C D E

Bottom of Door Trim Mantels

Fireplace

Hearth Louvre Assembly Top

Top of Combustion

Chamber

CFM146

F

10” (254mm)

K

11¹⁄₂” (292mm)

G

8” (203mm)

L

9¹⁄₂” (241mm)

H

6” (152mm)

M

7¹⁄₂” (191mm)

I

4” (101mm)

N

5¹⁄₂” (140mm)

J

2” (51mm)

O

3¹⁄₂” (89mm)

Fig. 4b Combustible mantel leg minimum installation.

Hearth

Although a hearth is not mandatory, one is recom- mended for aesthetic purposes. A noncombustible hearth which projects out 12” (305mm) or more from the front of the fireplace is recommended.

Mantel Chart

 

Mantel Shelf

 

Mantel from Top

Ref.

or Breast Plate

Ref.

of Comb. Chamber

 

Depth

 

 

V

10” (254mm)

A

19” (483mm)

W

8” (203mm)

B

17” (432mm)

X

6” (152mm)

C

15” (381mm)

Y

4” (101mm)

D

13” (330mm)

Z

2” (51mm)

E

11” (279mm)

Fig. 4a Combustible mantel leg minimum installation.

Cold Climate Installation Recommendation:

When installing this unit against a noninsulated exterior wall or chase, it is mandatory that the outer walls be insulated to conform to applicable insulation codes.

6

10002428

Page 6
Image 6
Vermont Casting DVRT43 manual Clearance to Combustibles, Mantels, Hearth, Vermont Castings, Majestic Products DVRT36/39/43