Vermont Casting DVRT43, DVRT39 Auto Path Chart, Vermont Castings, Majestic Products DVRT36/39/43

Models: DVRT39 DVRT36 DVRT43

1 50
Download 50 pages 26.47 Kb
Page 33
Image 33
Auto Path Chart

Vermont Castings, Majestic Products DVRT36/39/43

Auto Path Chart

LED Count

Service Action

8

Replace valve

7Confirm stepper motor connection exists

5Confirm fan connection exists and works

4Confirm gas type; jumper in place

3Replace thermopiles

2Turn fan ON

NOTE: Some keys are not active.

Auto Path

If the manual switch is

set to REMOTE,

press the mode button Auto Path to display AUTO on the Manual background

transmitter. Does the transmitter display the room and temperature setting?

Move switch from

LOCAL to REMOTE.

Press any key

within 30 seconds.

Yes

If the settings is above room temperature on the transmitter, did the main valve and fan turn On?

Yes

If the settings is below room temperature on the transmitter, did the main valve and fan turn Off?

Turn pilotstat knob to OFF to turn the valve completely Off.

No

No

10002428