Vermont Casting DVRT43, DVRT36, DVRT39 EB-1Electrical Box, Electronic Gas Control Valve, 10002428

Models: DVRT39 DVRT36 DVRT43

1 50
Download 50 pages 26.47 Kb
Page 9
Image 9
EB-1 Electrical Box

Vermont Castings, Majestic Products DVRT36/39/43

EB-1 Electrical Box

Electronic Gas Control Valve

The fireplace, when installed, must be electrically connected and grounded in accordance with local codes; or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code

For USA installations, follow the local codes and the national electrical code ANSI/NFPA No. 70.

It is strongly suggested that a licensed electrician perform the wiring of the EB-1 Electrical Junction Box.

Ensure that the power to the supply line has been disconnected before commencing this procedure.

The EB-1 Electrical junction box is fitted with this model to provide for easy installation of an optional fan kit.

To connect the EB-1 box to the house electrical supply follow the steps below:

1.Unscrew the retaining screw from the EB-1 base plate (Fig. 9), and remove the EB-1 assembly from the fireplace.

2.Remove the front cover of the EB-1 box.

3Remove the plug socket assembly from the EB-1 box.

4.Feed the supply line in from the outside through the cable clamp. (Fig. 9)

5.Connect black wire of the power supply line to the brass screw (polarized) of the socket assembly.

6.Connect the white wire of the power line to the chrome screw of the socket assembly.

7.Connect the ground wire of the supply line to the green screw of the socket assembly.

8.Refit the socket assembly back into the electrical box and replace the cover plate. Secure the cable with the clamp on the outside of the unit to prevent strain on the connections.

Inside

 

Electrical Box

 

 

 

 

 

Retaining Screw

 

 

 

 

 

Electronic Gas Control Valve Front of Unit

Outside

Front

of

Unit

 

FP580

 

 

Fig. 9 EB-1 receptacle.

This appliance may be fitted with a Honeywell ignition module.

Installation of the remote on/off starter switch on electronic ignition units:

1.Thread the wiring through the holes on the side panels of the appliance. Take care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box.

2.Attach the wire to the ON/OFF switch and install the switch into the receptacle box. (Fig. 10)

3.Connect the White wire from the wall switch to the Black wire from the transformer, using an approved wire nut. Connect the Black wire from the wall switch to the Black wire running from the #6 position of the ignition module, also using an approved wire nut.

 

PILOT

 

 

 

 

 

 

HONEYWELL IGNITION MODULE

 

 

 

 

24V

 

 

 

MV

MV/VP

PV

GRD

24V

SENSE

SPARK

1

2

3

5

6

8

9

 

 

 

GREEN

 

 

BLACK

RED

 

 

 

 

 

 

 

 

 

 

 

ORANGE

ORANGE

 

 

 

 

 

 

 

 

 

 

 

 

LO

 

 

 

 

 

 

HI

 

 

 

 

 

 

NOVA SIT 822 VALVE

 

 

BLUE

WHITE

 

 

 

 

 

POWER CORD

 

 

 

 

 

 

W/FEMALE SPADE

 

 

 

 

 

 

120 VAC RTN

24 VAC HOT

 

 

 

BLACK

 

 

 

 

 

 

WHITE

 

BLACK

 

 

 

OFF

 

 

 

 

 

 

WHITE

BLACK

 

YELLOW

 

 

 

 

GREEN

 

 

 

 

 

 

120 VAC HOT

24 VAC RET

 

 

 

 

40VA TRANSFORMER

 

 

 

 

WALL SWITCH

 

 

 

 

 

 

 

 

 

BLACK

WHITE

 

 

 

 

 

 

FP1225

Fig. 10 Honeywell ignition module.

10002428

9

Page 9
Image 9
Vermont Casting DVRT43 EB-1Electrical Box, Electronic Gas Control Valve, Vermont Castings, Majestic Products DVRT36/39/43