Check the fireplace to make sure it is leveled and properly positioned.

1.Choose the unit location.

2.Place the unit into position and secure it to the floor with 1¹⁄₂” (38mm) screws or nails. Holes for securing the unit to floor are located behind the access door grille on the left and right sides of the unit.

3.Frame in the fireplace with a header across the top. It is important to allow for the finished wall face when setting the depth of the frame.

4.Attach the fireplace to the frame using the adjustable frame drywall strips (located behind the access door for shipping). Preset the depth to suit the facing material of the wall. The strips are adjustable to 1/2” (13mm), 5/8” (16mm) or

3/4” (19mm). (Fig. 5)

5.Screw through the slotted holes in the drywall strip and into predrilled holes in fireplace side. Measure from face of fireplace to the face of the drywall strip to confirm the final depth.

 

C

Adjustable Drywall Strip

 

A

 

(Nailing Flange)

 

 

 

B

 

 

 

 

Screw

Drywall

 

 

Position

Depths

 

 

A

1/2” (13mm)

 

 

B

5/8” (16mm)

 

 

C

3/4” (19mm)

 

 

Adjustable

 

 

 

1/2” – 5/8” – 3/4”

 

 

Spacing

 

 

 

 

FP1023

Fig. 5

Adjustable drywall strip (nailing flanges).

Final Finishing

Noncombustible materials such as brick or tile may be extended over the edges of the face of the appliance.

DO NOT cover the window frame assembly, any vent, louvre assembly top or louvre assembly bottom.

If a Trim Kit is to be installed on the fireplace, the brick or tile will have to be installed flush with the edges of the appliance.

Gas Specifications

 

 

 

Max.

Min.

 

 

 

Input

Input

Model

Fuel

Gas Control

BTU/h

BTU/h

DVRT36RN

Nat

Millivolt

25,000

17,500

DVRT36RP

Prop

Millivolt

25,000

18,750

DVRT36EN

Nat

24V Hi/Lo

25,000

17,500

DVRT36EP

Prop

24V Hi/Lo

25,000

18,750

DVRT36RFN

Nat

Comfort Control

25,000

17,500

DVRT36RFP

Prop

Comfort Control

25,000

18,750

DVRT36RMH

Nat/ Prop

Millivolt

25,000

17,500

DVRT39RN

Nat

Millivolt

30,000

21,000

DVRT39RP

Prop

Millivolt

30,000

22,500

DVRT39EN

Nat

24V Hi/Lo

30,000

21,000

DVRT39EP

Prop

24V Hi/Lo

30,000

22,500

DVRT43RN

Nat

Millivolt

33,000

23,100

DVRT43RP

Prop

Millivolt

33,000

24,750

DVRT43EN

Nat

24V Hi/Lo

33,000

23,100

DVRT43EP

Prop

24V Hi/Lo

33,000

24,750

Gas Inlet and Manifold Pressures

 

Natural

LP (Propane)

Inlet Minimum

5.5” w.c.

11.0” w.c.

Inlet Maximum

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

 

 

 

DVRT36/ DVRT36RMH/ DVRT39/ DVRT43

Certified To

ANSI Z21.88-2002/ CSA 2.33-2002

Vented Gas Fireplace Heaters

High Elevations

Input ratings are shown in BTU per hour (BTU/h) and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level.

For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370 m).

10002428

7

Page 7
Image 7
Vermont Casting DVRT36, DVRT43 Framing & Finishing, Final Finishing, Gas Specifications, Gas Inlet and Manifold Pressures