Chateau™ Decorative Gas Appliance

Troubleshooting the Gas Control System

SIT 822 Valve with a Honeywell Electronic Ignitor

START

Turn Gas Supply Off

Turn On/Off Switch To Call For Heat "on"

Power To Module

(24V Normal)

YES

Spark Across

Ignitor Sensor Gap

YES

Turn Gas On Pilot Burner Lights?

YES

Spark Stops When

Pilot Is Lit?

YES

Main Burner Lights?

YES

System Runs Until

On/Off Switch Is In

"Off" Position

YES

Troubleshooting

Ends

NO• •Check: • Line Voltage (120vac)

Low Voltage Transformer (19.5 Minimum Vac)

On/off Switch

Wiring Connections

 

 

Unplug Ignition Lead

 

NO

 

NO

and Check Spark

 

• Replace Module

 

 

 

 

At Module

 

 

 

 

 

(24Vac Normal)

 

 

 

Spark OK?

YES

Check Ignition Cable Ground Wiring, Ceramic Insulator And Gap. Correct As Necessary

Check Boot Of Ignition Cable For Signs Of Melting Or Buckling. Take Protective Action To Shield

Cable And Boot From Excessive Temperatures.

NO

• Check That All Manual Gas Valves Are Open, Supply Tubing

 

 

 

 

And Pressures Are Good, And Pilot Burner Orifice

 

 

Is Not Blocked.

 

 

• Check Electrical Connections Between Module And

 

 

Pilot Operator On Gas Control.

 

 

• Check For 24vac Across Pv-mvpv Terminals On Module If

 

 

Voltage Is Okay, Replace Gas Control If Not, Replace

 

 

Module.

NO

NOTE: If S8600B Goes Into Lockout, Reset System.

 

 

Check Continuity Of Ignition Cable And Ground Wire.

Clean Flame Rod

Check Electrical Connections Between Flame Rod & Module.

Check For Cracked Ceramic Flame Rod Insulator.

Check That Pilot Flame Covers Flame Rod And Is Steady Blue

Adjust Pilot Flame.

If Problem Persists, Replace Module.

NO

• Check For 24vac Across Mv-mvpv Terminals If No

Voltage, Replace Module.

 

 

 

 

• Check Electrical Connections Between Module And Gas

 

 

 

 

Control. If Okay, Replace Gas Control, Or Gas Control

 

 

Operator.

NO

NOTE: If S8600B Goes Into Lockout, Reset System

Check For Continuity Of Ignition Cable And Ground Wire. Note: If Ground Is Poor Or Erratic, Shutdown May Occur Occasionally Even Though Operation Is Normal At The Time Of Checkout.

Check That The Pilot Flame Covers Flame Rod And Is Steady And Blue.

If Checks Are Okay, Replace Module.

20009543