All vegetation within 36” (914 mm) that may interfere with the draft.

NOTE: The collar extending down from the Termina- tion base is the air intake collar. Use the flex vent liner, marked with a blue line, to connect between this collar and the lower flue collar on the Transition Connector. Also make sure the other flex vent liner is attached to the upper Transition Connector collar and the Rain Cap. (Fig. 33)

1.

Clean the top of the chimney as needed, to ensure a

 

good seal between it and the vent termination.

2.

Slide the insulation sleeves provided in the termina-

 

tion kit over the two 3” flex liners (to be attached to

 

the 3” flue collar and cap of the termination assem-

 

bly).

3.

Feed 3” flex vent from the bottom of the termination

 

assembly up through the 4” sleeve. Apply high-tem-

 

perature sealant to the rain cap collar, and slide the

 

flex vent over the end of the rain cap collar, fastening

Fireplace Vent System

 

B

 

 

 

B

 

 

A

B

 

D

 

 

B C

C

A = Sealant Locations

B

 

C

 

A

B = Sheet Metal Screws

 

B

C = Termination Screws

 

D

 

A

D = Clamps

 

 

 

with the clamp provided.

4.

Slide the flex liner back through the 4” sleeve until

 

the rain cap/collar engages over the sleeve. Attach

 

the cap to the sleeve with three sheet metal screws

 

provided in the kit.

5.

Apply high-temperature sealant over the air intake

 

collar, and attach the intake flex vent (blue) with a

 

clamp.

6.

Apply high-temperature sealant to the top of the

 

chimney. Feed the two liners down through the

 

chimney flue and damper opening. Fasten the ter-

 

mination assembly to the chimney with the four set

 

screws (C) provided.

A

B

A D

A D B

ST395

7.

Trim the flex liners as needed. Each should be only

 

long enough to connect to the Transition Connector.

 

There should be no sag in either flex liner when the

 

stove is in place.

8.

Attach the flex liners to the Transition Connector, us-

 

ing high-temperature sealant and clamps as shown

 

in Figure 35. Prop the connector in rough position

 

until the heater is in place in front of it.

26"

(660 mm) 24"

(610 mm)

Fig. 33 Fireplace vent system installation.