Vent Opening - Combustible Wall

9³⁄"

(240mm)

9³⁄"

(240mm)

Vent Opening - Noncombustible Wall

7¹⁄"

(191mm)

VO584-100a

Fig. 23 Locate vent opening.

Attach the firestop plate to the sleeve end with the holes. (Fig. 24) NOTE: The wall sleeve is required in combustible walls only.

3.Install the Wall Firestop/Sleeve assembly into the wall cutout and fasten the firestop to the wall cutout framing members. (Fig. 24)

12”

 

(305mm)

Sleeve

Max. Length

 

 

#8 Sheet

 

Metal Screws

Firestop

ZCS103

 

Fig. 24 Assemble the wall sleeve and firestop.

 

4.If necessary, measure to determine the vertical length (X) of pipe required from the first (transition) elbow to the wall cutout centerline, including a 2” overlap at the joint. (Fig. 25) Use a hacksaw or tin snips to trim the pipe as needed.

5.Install first the inner then the outer straight pipe section(s), trimmed end down, to the point of the el- bow. Drill 3 holes through each joint and fasten with sheet metal screws.

6.Install the elbow using 3 sheet metal screws at each joint.

7.Measure, and cut if necessary, the appropriate length of pipe section needed to make the connec- tion through the wall. Include a 2” overlap; i.e. from the elbow to the outside wall face, about 2” or the distance required if installing a second 90° elbow. (Fig. 26)

Stardance Direct Vent - Rear Vent Gas Heaters

X

ST478

Fig. 25 Determine the vertical pipe length.

X

ST215

Fig. 26 Measure the horizontal length.

8.Slip the wall plate and trim collar over the interior end of the horizontal pipe and install into the wall sleeve. Seal the joint inside the wall plate if needed to keep cold air from being drawn into the home.

9.Connect the horizontal pipe to the elbow. Fasten the wall plate to the pipe with three sheet metal screws. Slide the trim collar up against the wall plate to cover the screws. (Fig. 27)

Trim Collar

Wall

 

Sleeve

ST216

Wall Plate

Fig. 27

Install the horizontal pipe and wall plate parts.