Vermont Casting SDDVRVG Gas Specifications, Gas Inlet and Manifold Pressures, High Elevations

Models: SDDVRMB SDDVRBD, SDDVRC, SDDVRCCB SDDVRCB SDDVRCBS SDDVRCVG SDDVRCH SDDVRCB, SDDVREB, SDDVRMB, SDDVRBS, SDDVRCH, SDDVRVG, SDDVRBD, SDDVRCCB, SDDVRCH, SDDVRCVG, SDDVRCBD SDDVREB SDDVRCMB SDDVRVG SDDVRBS SDDVRCBD SDDVRCEB SDDVRCCH

1 52
Download 52 pages 34.35 Kb
Page 8
Image 8

Stardance Direct Vent - Rear Vent Gas Heaters

Gas Specifications

 

 

 

Max.

Min.

 

 

 

Input

Input

Model

Fuel

Gas Control

BTU/h

BTU/h

SDDVR Series

Nat

Millivolt

21,000

15,000

SDDVR Series

Prop

Millivolt

21,000

16,000

SDDVRC Series

Nat

Comfort Control

21,000

15,000

SDDVRC Series

Prop

Comfort Control

21,000

16,000

 

 

 

 

 

Air Shutter Setting

Minimum rear injector air inlet openings.

Model

 

Natural Gas

 

LP

SDDVR/SDDVRC

 

1/2” Open

 

1/2” Open

Weight: Fully assembled 350 lbs.

 

 

 

 

 

 

 

Gas Inlet and Manifold Pressures

 

 

 

 

 

 

 

Natural

 

LP (Propane)

Inlet Minimum

5.5” w.c.

 

11.0” w.c.

Inlet Maximum

14.0” w.c.

 

14.0” w.c.

Manifold Pressure

3.5” w.c.

 

10” w.c.

 

 

 

 

 

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEP- TION: Do not derate this appliance for altitude. Main- tain the manifold pressure at 3.5” w.c. for Natural Gas and 10” w.c. for Propane.)

High Elevations

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level.

For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).

WARNING: Improper installation, adjust- ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.

Horizontal Termination

The vent must rise vertically a minimum of 24” (610mm) after the first elbow directly off the back of the unit, before the next elbow. The horizontal run may extend up to 20’ (6m) and include a vertical rise of up to 40’ (12m). (Fig. 7) Horizontal termination must also meet the criteria shown in Figures 9 and 10.

Approved vent systems must terminate above and including the heavy line in Figure 7.

Two 45° elbows may be substituted for each single 90˚ elbow.

With a rise between 2’ - 5’, one 90° or two 45° el- bows may be used (Excluding the first elbow directly off the back of the unit.

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27

 

 

 

 

 

 

 

 

 

 

Unacceptable

 

 

 

 

 

26

 

 

 

 

 

 

 

 

Venting Configuration

 

 

 

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

elbow)

23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vertical Run (in feet) Measured after the first elbow. (Transition

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

May use up to

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

three 90° Elbows

 

 

 

 

 

 

 

 

 

 

 

 

 

(Excluding elbow

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

directly off back

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

of unit.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

One 90°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Elbow*

 

 

 

 

 

 

 

Unacceptable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

Venting Configuration

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Horizontal Run (in feet)

ST134f

Fig. 7 Horizontal vent termination window.

* Not the transition elbow.

8

20012950

Page 8
Image 8
Vermont Casting SDDVRVG manual Gas Specifications, Gas Inlet and Manifold Pressures, High Elevations, Horizontal Termination