Maintenance and Troubleshooting

6.Install the new lamp module.

7.Replace the lamp cover and re-tighten all screws.

5.2

Filter Replacement

Whenever you replace the lamp – or more often if the projector is installed in an extremely dusty environment – you should also replace the filter located at the right side of the projector.

1.Loosen the two screws holding the filter access panel in place. Then, remove the panel.

2.Pull the filter out of the projector and discard. Do not reuse filters.

3.Insert the new filter with the pleats facing in and the foam-covered side facing out.

4.Replace the filter access panel and tighten the screws to secure it.

Side Filter

Access

Panel

64

Vidikron Vision Model 120 Installation/Operation Manual

Page 78
Image 78
Vidikron Vision 120 operation manual Filter Replacement