www.vxitech.com
Data is latched to the gate of the output coil drive FET dictating whether or not the FET will sink current and energize the relay coil. See the EX7000-OEM Manual (P/N: 82-0118-000) for more details.
INTERFACING WITH OTHER COMPONENTS
The EX7000 board set is capable of controlling other programmable components, such as filters and attenuators, through either the high-current channels or the 32-bit parallel I/O. Access to the control lines can be achieved in various ways. The high-current channels are available from the EX71HD and EX72SDF via pass-through switches that mount on the front panel in place of one or more switches. These switches consist of a flat mounting plate with mounting holes to match the multi-throw switch it replaces. A multi-pin connector is mounted to the plate and the connector is wired directly to one of the relay driving connectors, allowing external use by the user.
In addition to the high-current control lines, the EX72SF also has a front panel mounted, 32-channel, TTL-level, general purpose IO bus available. Refer to Section 3 for details or obtain a copy of the EX7000-OEM Manual for more information on this bus. Contact the factor or visit the VXI Technology, Inc. website for a copy of this document.
FEATURES
Relay Odometer
Each relay drive line has an associated “odometer” which tracks the number of times a relay coil has been actuated. This data is written to non-volatile memory and can be called from application code or the web interface. This assists preventative maintenance programs as relays can be closely monitored as they near end-of-life.
Exclude Lists
The supplied API supports the implementation of exclude lists. Undesirable combinations of relay closures can be stored and warnings or errors will be generated any time an excluded combination is attempted. This helps prevent unsafe conditions such as shorting sources to ground or coupling one source to another.
Scan Lists
Up to 16,000 scan list elements can be stored to help reduce overhead that can be accrued when relying on the host controller to manage the sequencing of switch states. A predefined list of switch states can be stored on-board and advanced through hardware control/handshaking with external system devices via the LXI Trigger Bus or the GP digital I/O port. Use of scan lists can considerably speed up test execution times.
Configuration Table
The information included in the Configuration File allows the user to establish a complete signal route by indicating only the end points in a compliant IVI-Switch Connect statement, thus simplifying the programming task
Programmable MBB and BBM
The application code can globally define whether or not the relays ‘break-before-make’ or ‘make- before-break’ when sequencing through relay setups.