Part Number

www.vxitech.com

Part Number

Bank 0

Bank 1

Bank 2

-000

Open-collector

Open-collector

Open-collector

-001

TTL

Open-collector

Open-collector

-002

TTL

TTL

Open-collector

-003

TTL

TTL

TTL

CAUTION

It is imperative that TTL banks only have TTL devices connected to them. Connecting an open-collector device to a TTL port will result in damage to the RDB and, potentially, to other equipment in the test system. Failure to comply with this warning will result in voiding the manufacturer’s warranty.

RELAY ACCESS & CONTROL

FIGURE 5-3: RELAY DRIVER BLOCK DIAGRAM

When asserted, the relay drive lines will sink the necessary current through the coils, effectively switching the relay. The user can program the relay settling time for each RDB.

The relay control can be operated in two modes: Pulse and Continuous

Continuous Mode

Connecting non-latching devices to any bank of the RDB will dictate that bank must be operating in continuous mode. Commanded by software, the latch signal driving the FET will change state to activate/deactivate FETs and continuously stay in that state until the next command. All Relay Control Drive bits within a bank will change state at the same time. Continuous mode requires a power supply capable of sustaining the high-current requirement. The user must allow an appropriate amount of time after the Relay Control Drive bit changes state for the relay to settle. This is typically between 10 ms to 30 ms.

EX7000 Series Web Page Operation

37