11
Tools Needed:
Ratchet Wrench
Tape Measure
Power Drill
3/16” Drill Bit
7/16” Socket
Driver
7/16” Wrench
Pencil
Wired Infrared Safety Sensor
Installation
IMPORTANT: BOTH WALL BRACKETS MUST BE MOUNTED AT THE SAME HEIGHT FOR PROPER ALIGNMENT.
Note: Use Steps
a. Select and mark with a pencil, a mounting location no more than
5 inches above the floor to center line of wall mounting bracket. The safety sensors should be mounted as close to the door track or inside edge of the door as possible to offer maximum entrapment protection. It is very important that both wall mounting brackets be mounted at the same height for proper alignment.
b. Drill pilot holes, using a 3/16” drill bit. Using two 5/16” x
Wall Mounting Bracket
5”
a |
|
|
b | Door Jam |
|
|
| 5/16” x |
| Wall Mounting | Lag Screw |
|
| |
| Bracket |
|
| Nut |
|
Attach the “U” brackets to the wall mounting brackets with
IMPORTANT: IDENTIFY WHICH SIDE OF THE GARAGE DOOR IS EXPOSED TO THE MOST SUNLIGHT. MOUNT THE SENDING UNIT (UNIT WITHOUT LED) ON THE SIDE WHICH IS EXPOSED TO THE MOST SUN. SUNLIGHT MAY AFFECT THE SAFETY SENSORS, AND THIS ORIENTATION WILL HELP REDUCE THE EFFECT.
c. Attach the sending and receiving safety sensors to the “U” brackets by inserting all three tabs into the respective holes.
Washer
c
Receiving | LED |
Unit |
|
Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need 9 You can reach us Toll Free at