I

Adjustment # 1 Opening and Closing Force

This garage door opener is built with a safety system that allows the door to reverse when closing and stop when opening. This must be adjusted so your opener does not use excessive force in the down direction or react to the weight of the door during upward travel.

CLOSING FORCE ADJUSTMENT

To help determine that the closing door force is not excessive, grasp the door handle or bottom edge during downward travel. The opener should REVERSE to this force.

Adjustments

Adjustment # 2 Contact Obstruction Sensing (Closing Direction)

The opener is designed to automatically reverse the door during closing travel whenever it comes in contact with a 2 x 4 laid flat on the floor. An object on the floor with a height less than 1-1/2” will not cause the door to reverse. (Test according to instructions in Step 21.)

If opener reverses properly with a 2 x 4 laid flat on the garage floor (Step 21) and stops without the solid test object in the fully closed position, proceed to Adjustment # 3.

NOTE: Do not stand under door during this test.

To adjust the closing force follow one of the two methods listed below.

Method A (manual)

1.Turn the FORCE ADJ. counter clockwise to decrease force and reversal test until door reacts properly.

PROGRAM

SW STATUS

 

FORCE ADJ.

Program Status

LED

Program

Button

Closing Force

Adjustment

repeat

When door comes in contact with a 2 x 4 laid flat on the garage floor and stops instead of reversing, reset the door close limits according to instruction in Step 19, adjusting until door reverses upon contact with a 2 x 4 laid flat on the garage floor.

If door reverses when it comes in contact with the floor, reset the door close limits according to instruction in Step 19.

Adjustment # 3 Positive Mechanical Door Lock

Method B (computer assisted)

1.Operate the door to the fully open position.

2.Turn the FORCE ADJ. counter clockwise to the minimal force setting.

3.Press the PROGRAM button two times or the PROGRAM

button on the Wireless Wall Station (if included) until the LED turns on solid (5 sec.). The STATUS LED and the overhead lamp will flash on and off at a slow rate.

4.Operate the door to the fully closed position.

5.Turn the FORCE ADJ. clockwise until the STATUS LED flickers or just turns off.

6.Press the PROGRAM button once to confirm setting.

OPENING FORCE ADJUSTMENT

To determine that the opening force is not excessive, grasp the door handle or bottom edge during upward travel. If the opener does not stop or is hard to hold, decrease the open force setting. The opener should STOP without using excessive force.

To change the opening force follow the procedure listed below.

1.Operate the door to the fully closed position.

2.Press the PROGRAM button three times. The STATUS LED

and the overhead lamp will flash on and off. The blink rate, which corresponds to the force setting, will consist of 1 to 5 fast blinks followed with a long pause between blink sequences.

3.The first time an attempt is made to increase the force, the setting will begin at the lightest setting (1 blink).

4.To increase the force, press and release the door up/down button on any control (The STATUS LED will remain lit during button press).

5.Continue to press and release the door button until the desired force setting is achieved.

6.Press the PROGRAM button once to confirm setting.

The garage door opener is designed with an automatic mechanical locking system. This lock secures the door in the fully closed position.

To adjust, activate the door opener and allow the door to go to its fully closed position. Loosen the two screws on the rail stop and move it behind the latch assembly with a gap of 3/4” between “stop” and “latch”. Retighten screws.

Screws

3/4”

Rail “Stop”

“LATCH”