Installation

To make the neutral connections:

1.Ensure there is only one neutral-to-ground bond in the system. In this case, it would be in the main AC distribution panel.

Important: Ensure there is only one neutral-to-ground bond in the entire system. See the Sine Wave Plus Inverter/Charger Owner’s Manual for additional information regarding the neutral-to-ground bond requirements.

2.Connect the neutral (white) wire from the neutral bar in the main AC distribution panel to one of the neutral terminals in the ACCB.

3.Connect the factory-installed neutral wire (white) in the ACCB to the NEU1 terminal in the inverter.

4.Connect the neutral (white) wire from the generator and connect it to one of the neutral terminals in the ACCB.

5.Route and connect a neutral (white) wire from one of the neutral terminals in the ACCB to the outlet that will be supporting the AC load.

1

4

2

3

5

Figure 1-32Neutral Connections for an On-Grid Application Using Additional Circuit Breakers in the ACCB Only