Power Sources for the Conext ComBox
Conext ComBox with Remote Access
You can access the web user interface for the Conext ComBox from a remote computer using the Internet. The Conext ComBox must be connected to a router. The router firewall settings must allow port forwarding, which allows the remote computer to access the Conext ComBox using the router’s IP address and the port number for the Conext ComBox.
Note: There is a security risk in port forwarding unencrypted network traffic over a public network (Internet). It is recommended you use a VPN or a secure tunnel to route Conext ComBox communication via the Internet.
FREEDOMSW 2000 |
|
|
|
|
|
| Router | Internet |
|
Xanbus cables | Conext ComBox | Ethernet Cables | Laptop or Tablet |
Power Sources for the Conext ComBox
The Conext ComBox consumes an average of 2 W under most operating conditions and up to 10 W maximum. The power sources connected to the Conext ComBox must be capable of providing this power requirement.
There are three power sources for the Conext ComBox:
•AC/DC power adapter (supplied)
•Freedom SW inverter/charger via CAT5 or CAT5e cable (Xanbus cable)
•24 V DC power input connections on the RS 485 Modbus connector
All three sources can be used alone or simultaneously. Typically, the supplied
AC/DC power adapter is used as a primary source with either a Xanbus or a
RS 485 Modbus connection as secondary sources.
Note: Modbus support is available only for the Conext ComBox (Part Number
The RS 485 Modbus connector supplied with this Conext ComBox – Freedom
SW (Part Number 809- 0918), is not required for operation or supported by
Xantrex technical support.