Error Code Table
Error | Description of Fault | Possible Cause | Solution |
Code |
|
|
|
|
|
|
|
002 | Battery Voltage is too low | 1. Discharged battery. | 1. Charge battery. |
|
| 2. Old or faulty battery. | 2. Battery may not be hold- |
|
|
| ing charge properly. If |
|
|
| flooded, check electro- |
|
|
| lyte level and fill with dis- |
|
|
| tilled water if necessary. |
|
|
| Equalization may help if |
|
|
| recommended by the bat- |
|
|
| tery manufacturer. Battery |
|
|
| may be faulty and require |
|
|
| replacement. |
|
| 3. Battery cables to the Pros- | 3. Check cable size and |
|
| ine inverter/charger are too | length against recom- |
|
| small, too long, or there is a | mendations in this man- |
|
| loose connection. | ual. Check and tighten all |
|
|
| connections. Large loads |
|
|
| may draw the voltage |
|
|
| down very quickly on a |
|
|
| small battery or in an |
|
|
| installation with cables |
|
|
| that are too small or too |
|
|
| long. |
|
|
|
|
003 | Battery Voltage is too high. | 1. External charger or alterna- | 1. Correct or disconnect the |
|
| tor has output voltage | external charging source. |
|
| greater than 16 V. |
|
|
| 2. A 12V Prosine inverter/ | 2. Make sure the battery |
|
| charger could be connected | bank is nominal 12V for a |
|
| to a 24V battery (two batter- | 12v Prosine. |
|
| ies in series). |
|
|
|
|
|
006,065 | Microprocessor communi- | Remote display cable is | Check display cable con- |
| cation error. | pinched or has loose connec- | nections and attempt |
|
| tion. | restart. If the problem per- |
|
|
| sists, try a replacement |
|
|
| cable. |
|
|
| If the problem persists, call |
|
|
| Xantrex. |
|
|
|
|
90 | Prosine 2.5/3.0 Installation & Operation Guide |