ACS Configuration

ACS Configuration

The ACS Control Panel enables you to configure the Prosine inverter/charger to your particular installation. All of the ACS Control Panel menus (except Version Information) contain one or more configurable parameters. Each configuration parameter is discussed in the appropriate menu section that follows.

User Configuration Items

CAUTION Do not change the configuration of your Prosine if you are uncertain of your changes. If you are uncertain of the effects of your changes, read the entire manual, then consult a qualified installer or call Xantrex Customer Assistance.

For User Configuration items, press ENTER to select the parameter you want to change, and then an arrow key to change the value. Set the value by pressing ENTER.

Installer Configuration Items

WARNING Risk of battery damage and fire or explosion: An “installer settable” configuration item is meant to be configured by a professional installer who is familiar not only with the system settings of the inverter, but also the ramifications of changing those system settings. Setting these parameters incorrectly can cause damage to your equipment or severely affect the performance of your system.

To enter Installer Mode:

1.Scroll the display until the parameter to be changed is visible.

2.Press and hold down the ESCAPE and DOWN ARROW keys until the panel beeps.

3.Press ENTER.

4.Use the UP and DOWN ARROW keys to change the parameter as appropriate.

5.To store the change, press ENTER.

After a change is stored, the inverter/charger will remain in Installer Mode. To change additional parameters, select the parameter and repeat steps 3, 4 and 5.

To exit Installer Mode:

Press the ESCAPE key repeatedly until you reach the main menu.

If you want to change another installer-settable parameter after reaching the main menu, follow the keypress sequence (steps 1, 2 and 3) to enter Installer Mode again.