ACS Configuration Considerations

System Configuration

The System Information menu contains two configuration items: System Startup Default and Audible Alarm. Both are user configuration items and are selected by pressing ENTER.

System Startup Default You can set the initial power-up configuration when AC shorepower is provided to the Prosine inverter/charger so that the inverter and charger are either both On, both Off, or one is On and the other is Off. This is a User configuration item set by pressing ENTER, scrolling to the desired value by pressing an arrow key, pressing ENTER to select the value, and pressing ESCAPE to exit the menu. The indicates the current selection.

SELECT FROM: SYSTEM INFO

ENTER

SYSTEM INFO: DEFAULT INV/CHG

DEFAULT INV/CHG

INV ON/CHG ON

DEFAULT INV/CHG INV OFF/CHG OFF

DEFAULT INV/CHG INV OFF/CHG ON

DEFAULT INV/CHG INV ON/CHG OFF

ENTER

ENTER

Audible Alarm The System Info menu also allows you to turn the audible alarm Off or On. The audible alarm sounds any time there is an inverter/charger fault, or when the DC high- or low-voltage range is exceeded. If equipped with a battery temperature sensor, the audible alarm will also sound when battery temperature is less than -15°C (5°F) or more than 50°C (122°F). The audible alarm is always accompanied by flashing LEDs and an error code display. The alarm is ENABLED at the factory.

SELECT FROM: SYSTEM INFO

ENTER

SELECT FROM: ALARM AUDIBLE

AUDIBLE ALARM: ENABLED

AUDIBLE ALARM:

DISABLED

ENTER

ENTER

36

Prosine 2.5/3.0 Installation & Operation Guide