Appendix C: Troubleshooting

 

 

 

 

 

 

 

Error

Description of Fault

Possible Cause

Solution

 

Code

 

 

 

 

 

 

 

 

 

 

206

AC Output voltage too high

1. Some loads, like motors,

1. Try resetting the unit and

 

 

 

can feed power back into

running the load again.

 

 

 

the output of the Prosine.

Contact Xantrex if you

 

 

 

This may result in a tempo-

find consistent incompati-

 

 

 

rary over-voltage which

bility with a certain type of

 

 

 

may trigger a fault condi-

load.

 

 

 

tion.

2. Record the error code

 

 

 

2. There is an internal hard-

and contact Xantrex.

 

 

 

ware or software fault.

 

 

 

 

 

 

 

 

207

Internal DC Bus voltage is

1. Temporary condition

1. Check if battery is OK

 

 

low in invert mode.

caused by low battery volt-

(see error code 002). Dis-

 

 

 

age in conjunction with an

connect AC and DC

 

 

 

overload condition.

power to the Prosine.

 

 

 

 

Reconnect DC and AC

 

 

 

 

power after 15 minutes. If

 

 

 

 

the problem persists, con-

 

 

 

 

tact Xantrex.

 

 

 

2. Internal Fault.

2. Record the error code

 

 

 

and contact Xantrex.

 

 

 

 

 

 

 

 

 

 

Prosine 2.5/3.0 Installation & Operation Guide

93