| Appendix C: Troubleshooting |
| |
|
|
|
|
| |
| Error | Description of Fault | Possible Cause | Solution | |
| Code |
|
|
|
|
|
|
|
|
| |
| 206 | AC Output voltage too high | 1. Some loads, like motors, | 1. Try resetting the unit and | |
|
|
| can feed power back into | running the load again. | |
|
|
| the output of the Prosine. | Contact Xantrex if you | |
|
|
| This may result in a tempo- | find consistent incompati- | |
|
|
| rary | bility with a certain type of | |
|
|
| may trigger a fault condi- | load. | |
|
|
| tion. | 2. Record the error code | |
|
|
| 2. There is an internal hard- | and contact Xantrex. | |
|
|
| ware or software fault. |
|
|
|
|
|
|
| |
| 207 | Internal DC Bus voltage is | 1. Temporary condition | 1. Check if battery is OK | |
|
| low in invert mode. | caused by low battery volt- | (see error code 002). Dis- | |
|
|
| age in conjunction with an | connect AC and DC | |
|
|
| overload condition. | power to the Prosine. | |
|
|
|
| Reconnect DC and AC | |
|
|
|
| power after 15 minutes. If | |
|
|
|
| the problem persists, con- | |
|
|
|
| tact Xantrex. | |
|
|
| 2. Internal Fault. | 2. Record the error code | |
|
|
| and contact Xantrex. | ||
|
|
|
| ||
|
|
|
|
|
|
Prosine 2.5/3.0 Installation & Operation Guide | 93 |