Section 5: Operation
Input Voltage: The Prosine inverter/charger operates from an input voltage ranging from 10 volts to 16 volts, (20 to 32 volts on 24V models) and peak performance occurs when voltage is in the range of 12 volts to 13 volts (24 to 26 volts on 24V models) as shown in the following table.
Prosine Operating Voltage Limits
Operating | Voltage Range | Voltage Range | ||
Condition | ||||
Normal | 10V - 16V | 20V | - 32V | |
Peak Performance | 12V - 13V | 24V | - 26V | |
High Voltage Alarm |
|
|
|
|
LED On | >15.5V | >31V | ||
Unit Shuts Down | >16V | >32V | ||
Low Voltage Alarm |
|
|
|
|
LED Flashes | ≤ 10.5 | V | ≤ 21V | |
Unit Shuts Down | ≤10.0 | V | ≤20 | V |
Unit Restarts | ≥12.3 | V | ≥24.6 | V |
Prosine 2.5/3.0 Installation & Operation Guide | 57 |