Section 3: Configuration
Battery Configuration
The Battery Information menu has three configuration parameters: Battery Type, Battery Size, and Battery Temperature. All of these parameters have an effect upon the optimal charging regime. For a comprehensive discussion about batteries, see “Section 7: Batteries”.
WARNING Risk of battery damage and fire or explosion if using the wrong battery type or size setting.
Battery TypeNOTE: This is an
use with the Prosine inverter/charger: flooded
NOTE: This is an
The amount of current your batteries can absorb while charging is directly related to their temperature. The ambient temperature affects the amount of current that will pass into and out of the batteries. You can set the battery temperature to optimize the Prosine charging regime for cold, warm, or hot ambient temperatures. Xantrex strongly recommends use of the included Battery Temperature Sensor that enables the Prosine inverter/charger to automatically adjust the charging regime for temperature. When the temperature sensor is installed, the Battery Temperature setting is ignored. You can switch between the Celsius (C) and Fahrenheit scales by pressing ENTER and then ▼ or ▲ but use of the battery temperature sensor is preferred.
Cold = <10°C (50°F), Warm = 10°C to 27°C (50°F to 80°F), Hot = >27°C (80°F)Battery temperature can be set in the usual way: by entering the menu, scrolling to the desired value, and accepting the value by pressing ENTER.
BATTERY INFO: TEMP: WARM
ENTER
BATTERY INFO: TEMP: HOT
ENTER
Battery type and size parameters are installer configuration items. Enter Installer Mode, then enter the menu, and set the value as above. Press ENTER to accept the value and ESCAPE to exit the menu.
Prosine 2.5/3.0 Installation & Operation Guide | 31 |