Error Code Table
Error | Description of Fault | Possible Cause | Solution |
Code |
|
|
|
|
|
|
|
195 | Internal DC bus voltage is | 1 There may be a hot to | 1. Contact Xantrex and |
| low in Charge mode | ground wiring error. A mis- | return unit for repair. |
|
| take made in AC wiring |
|
|
| caused internal traces to |
|
|
| open. Shoring the AC line to |
|
|
| the chassis ground occasion- |
|
|
| ally causes damage espe- |
|
|
| cially if supplied from a 50 A |
|
|
| service with a short cord. | 2. Record the error code |
|
| 2 Internal fault | |
|
| and contact Xantrex. | |
|
|
| |
|
|
|
|
196 | Internal fault | Various. There could be a | Record the error code and |
|
| fault inside the unit or the | contact Xantrex. |
|
| microprocessor is fooled by |
|
|
| some external condition. |
|
|
|
|
|
197 | Unexpected AC output volt- | AC Input Line and Neutral are | Check AC Input wiring. |
| age | reversed. | There should be less than |
|
|
| 5V RMS between AC Input |
|
|
| Neutral and Earth Ground. |
|
|
| If you measure higher volt- |
|
|
| age from neutral to ground, |
|
|
| then the AC shorepower |
|
|
| source likely has reversed |
|
|
| polarity and requires cor- |
|
|
| rection. |
|
|
| Long and/or loose connec- |
|
|
| tions to the utility/shore- |
|
|
| power can result in a high |
|
|
| neutral voltage as well. |
|
|
| Check connections and |
|
|
| repair as necessary. |
|
|
|
|
Internal fault | Various. There could be a | Record the error code and | |
|
| fault inside the unit or the | contact Xantrex. |
|
| microprocessor is fooled by |
|
|
| some external condition. |
|
|
|
|
|
202,203 | Relay Contact Fault | One of the relay contacts is | Record the error code and |
|
| stuck in the closed position. | contact Xantrex. |
|
|
|
|
204 | AC Input Neutral Warning | AC Input Neutral voltage is | See Fault Code 197. |
|
| greater than 10 V with respect |
|
|
| to Earth Ground. |
|
|
|
|
|
205 | Internal fault | Various. There could be a | Record the error code and |
|
| fault inside the unit or the | contact Xantrex. |
|
| microprocessor is fooled by |
|
|
| some external condition. |
|
|
|
|
|
92 | Prosine 2.5/3.0 Installation & Operation Guide |