3)Connect both the garden hose adapter and a water tap using a hose.

4)Start the engine. Then, immediately turn on water supply until the water flows out continually from the cooling water pilot outlet.

5)Run the engine at an idle speed for 10 to 15 minutes watching engine condi- tion.

If the engine stopped while flushing, turn off water supply immediately. Repeat above steps.

6)Turn off the water supply. Then, force the remaining water out from the cooling passages by quickly opening and closing the throttle several times within 10 to 15 seconds.

7)Stop the engine.

8)Remove the garden hose adapter and secure the cap.

4-2