Using the tool buttons
37
M7CL Owner’s Manual
Basic operation of the M7CL
3
If you use the channel number / channel name buttons
in the 8 ch/ALL popup window, you can select multi-
ple channels by selecting a region. In this case, the
same library data will be recalled to all of the selected
channels.

[GEQ/EFFECT popup window]

Use the rack select tabs at the bottom of the popup
window to select a rack.
3Press the LIBRARY tool button to open the

corresponding library window.

Library windows contain the following items.

1CURRENT TYPE (only for the output

channel library)

This field displays the type of channel selected via the
[SEL] key.

BList

This shows the data saved in the library. A highlighted
line indicates that it is selected for operations. Read-
only data is indicated by an R symbol.

CRECALL button

This recalls the data selected in the list into the cur-
rently selected channel (EQ/dynamics) or rack (GEQ/
effect).
4By turning any one of the multifunction

encoders, move the highlighted line in the

list to select the library item you want to

recall.

Depending on the data you’ve selected for recall, it
may not be possible to recall it into the currently
selected channel or rack. Each library has the follow-
ing restrictions.
Channel library
If the type of channel selected via the [SEL] key is
different from the one selected in the list in the out-
put channel library, “CONFLICT” appears to the
right of CURRENT TYPE. You can recall the data
even if “CONFLICT” appears, although the data
would include different parameters. Parameters that
do not exist in the library will be set to the default
value.
Dynamics library
The dynamics library contains three types of data;
Dynamics 1 and Dynamics 2 for input channels, and
Dynamics 1 for output channels. You can’t recall the
data if an inappropriate type of dynamics data is
selected in the library.
GEQ library
The GEQ library contains two types of data;
31BandGEQ or Flex15GEQ. You can’t recall the
data if the type selected in the library is different
than the type of the recall-destination GEQ.
Effect library
Effect library items that use effect types “HQ.Pitch”
and “Freeze” can be recalled only to rack 5 or 7.
These cannot be recalled if any other rack is
selected.
If you select a library number that cannot be recalled,
it will not be possible to press the RECALL button.
Selected region
Rack select tabs
•You can’t select a rack select tab of a rack in which no GEQ
or effect is mounted.
NOTE

3

2
1
The right side of the list displays information regarding the
relevant setting data (such as the type of output channels,
dynamics type or effect type being used). About the corre-
sponding data. The dynamics library also displays symbols
indicating whether the data can be recalled into Dynamic 1
and/or Dynamics 2.
HINT