Yamaha YSP-1000 Error messages for AUTO SETUP, Cause, Remedy, page, ERROR E-2, ERROR E-1

Models: YSP-1000

1 102
Download 102 pages 35 Kb
Page 37
Image 37
■Error messages for AUTO SETUP

AUTO SETUP

Error messages for AUTO SETUP

Before the AUTO SETUP procedure starts

Error message

Cause

Remedy

See

page

 

 

 

 

 

 

 

ERROR E-2

The optimizer microphone is not

Connect the optimizer microphone to

29

No MIC Detected. Please check

connected to this unit.

this unit.

 

MIC connection and re-try.

 

 

 

 

 

 

 

While the AUTO SETUP procedure is in progress-

 

 

 

 

 

 

Error message

Cause

Remedy

See

page

 

 

 

 

 

 

 

ERROR E-1

There is too much unwanted noise in

Make sure that your listening room is as

Please test in more quiet

your listening room.

quiet as possible. You may want to

 

environment.

 

choose certain hours during the day

 

 

 

when there is not much noise coming

 

 

 

from outside.

 

 

 

 

 

ERROR E-2

The optimizer microphone was

Make sure that the optimizer microphone

29

No MIC detected. Please check

disconnected while the AUTO SETUP

is firmly connected to this unit.

 

MIC connection and re-try.

procedure was in progress.

 

 

 

 

 

 

ERROR E-3

Some other operations were performed

Do not perform any other operations

Unexpected control is detected.

on this unit while the AUTO SETUP

while the AUTO SETUP procedure is in

 

Please re-try.

procedure was in progress.

progress.

 

 

 

 

 

ERROR E-4

The optimizer microphone is not placed

Make sure that the optimizer microphone

29

Please check MIC position. MIC

in front of this unit.

is installed in front of this unit.

 

should be set in front of YSP.

 

 

 

 

 

 

 

ERROR E-5

The optimizer microphone is not placed

Make sure that the optimizer microphone

29

Please check MIC position. MIC

in the right distance from this unit.

is installed more than 2 m from the front

 

should be set above 2m/6.5ft.

 

of this unit and within 1 m from the

 

 

 

center height of this unit.

 

 

 

 

 

ERROR E-6

The optimizer microphone cannot collect

Make sure that the optimizer microphone

29

Volume level is smaller than

the sound produced by this unit because

is firmly connected to this unit and

 

expected. Please check MIC

the sound output level is too low.

placed in a proper location. If the

 

position/connection and re-try.

 

problem persists, contact the nearest

 

 

 

YAMAHA service center for assistance.

 

 

 

 

 

ERROR E-7

An internal system error occurred.

Repeat the AUTO SETUP procedure.

Unexpected Error Happened.

 

 

 

Please re-try.

 

 

 

 

 

 

 

SETUP

English

35

Page 37
Image 37
Yamaha YSP-1000 Error messages for AUTO SETUP, Cause, Remedy, page, ERROR E-2, No MIC Detected. Please check, ERROR E-1