York DFAH, DFAA Sizing Furnace Input, UIM-B-1105, Natural Gas, Propane Gas, Firing Rate, Orifice

Models: DFAA DFAH

1 40
Download 40 pages 47.88 Kb
Page 32
Image 32
NATURAL GAS

107272-UIM-B-1105

TABLE 18: High Altitude Duration Chart

NATURAL GAS

Elevation

 

 

56,000 — Input

 

70,000 — Input

 

77,000 — Input

 

90,000 — Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice

Drill

 

 

Orifice

 

Drill

 

 

Orifice

Drill

 

 

Orifice

Drill

 

 

Feet

 

Meters

Part #

 

Part #

Part #

Part #

 

 

 

Dia.

Size

 

 

Dia.

 

Size

 

 

Dia.

Size

 

 

Dia.

Size

 

 

Sea Level

 

0.136

29

9951--

1361

0.154

 

23

9951--

1541

0.161

20

9951

--1611

0.180

15

9951--

1801

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2,000

 

618

0.136

29

9951--

1361

0.149

 

25

9951--

1491

0.157

22

9951--

1571

0.177

16

9951--

1771

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3,000

 

914

0.128

30

9951--

1281

0.149

 

25

9951--

1491

0.157

22

9951--

1571

0.173

17

9951--

1731

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4,000

 

1219

0.128

30

9951--

1281

0.147

 

26

9951--

1471

0.154

23

9951--

1541

0.173

17

9951--

1731

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5,000

 

1524

0.128

30

9951--

1281

0.144

 

27

9951--

1441

0.152

24

9951--

1521

0.169

18

9951--

1691

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6,000

 

1829

0.128

30

9951--

1281

0.144

 

27

9951--

1441

0.149

25

9951--

1491

0.166

19

9951--

1661

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7,000

 

2134

0.120

31

9951--

1201

0.140

 

28

9951--

1401

0.147

26

9951--

1471

0.161

20

9951--

1611

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8,000

 

2438

0.120

31

9951--

1201

0.136

 

29

9951--

1361

0.144

27

9951--

1441

0.161

20

9951--

1611

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9,000

 

2743

0.120

31

9951--

1201

0.136

 

29

9951--

1361

0.140

28

9951--

1401

0.157

22

9951--

1571

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10,000

 

3048

0.116

32

9951--

1161

0.128

 

30

9951--

1281

0.136

29

9951--

1361

0.152

24

9951--

1521

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROPANE GAS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Elevation

 

 

56,000 — Input

 

70,000 — Input

 

77,000 — Input

 

90,000 — Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice

Drill

 

 

Orifice

 

Drill

 

 

Orifice

Drill

 

 

Orifice

Drill

 

 

Feet

 

Meters

Part #

 

Part #

Part #

Part #

 

 

 

Dia.

Size

 

 

Dia.

 

Size

 

 

Dia.

Size

 

 

Dia.

Size

 

 

Sea Level

 

0.082

45

9951--

0821

0.093

 

42

9951--

0931

0.098

40

9951--

0981

0.106

36

9951--

1061

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2,000

 

618

0.081

46

9951--

0811

0.093

 

42

9951--

0931

0.096

41

9951--

0961

0.104

37

9951--

1041

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3,000

 

914

0.078

47

9951--

0781

0.089

 

43

9951--

0891

0.093

42

9951--

0931

0.101

38

9951--

1011

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4,000

 

1219

0.078

47

9951--

0781

0.089

 

43

9951--

0891

0.093

42

9951--

0931

0.101

38

9951--

1011

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5,000

 

1524

0.078

47

9951--

0781

0.089

 

43

9951--

0891

0.093

42

9951--

0931

0.099

39

9951--

0991

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6,000

 

1829

0.076

48

9951--

0761

0.086

 

44

9951--

0861

0.089

43

9951--

0891

0.098

40

9951--

0981

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7,000

 

2134

0.076

48

9951--

0761

0.086

 

44

9951--

0861

0.089

43

9951--

0891

0.096

41

9951--

0961

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8,000

 

2438

0.073

49

9951--

0731

0.082

 

45

9951--

0821

0.086

44

9951--

0861

0.096

41

9951--

0961

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9,000

 

2743

0.073

49

9951--

0731

0.081

 

46

9951--

0811

0.086

44

9951--

0861

0.093

42

9951--

0931

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10,000

 

3048

0.070

50

9951--

0731

0.078

 

47

9951--

0781

0.082

45

9951--

0821

0.089

43

9951--

0891

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table shows 4% Input Reduction per 1,000 ft. (304.8 m) Elevation. Reference Source: NFPA No. 54, ANSI Z 223.1, National Fuel Gas Code.

For Canadian high altitude {2000 - 4500 ft. (609.6 - 1,371.6)}, reduce gas manifold pressure to 3.0” w.c. (0.75 kPa) for Natural gas and for Propane gas.

SIZING FURNACE INPUT

The orifice spud supplied with all burners is the size for the minimum BTU input of the burner for the type gas shown on the rating plate. Table 18 shows the correct drill size for various inputs.

The correct manifold pressure for natural and LP gas is 3.5" w.c (0.87 kPa). Only minor adjustments in the input rate should be made by adjusting the pressure regulator. The minimum manifold pressure should be 3.0" w.c. (0.75 kPa) and the maximum pressure should be

3.5w.c. (0.87 kPa) the next size larger or smaller orifice size should be used if the desired input rating cannot be obtained within the above manifold pressure adjustment range.

TABLE 19: Gas Burner Settings

Gas

Firing Rate

Orifice

Air Shutter

(@ 3.5” W.C.)

BTU/Hr (kw)

Size

Setting

 

 

 

 

Natural

66,000 (19.3)

0.142” (3.61mm)

1.0

 

 

 

 

Natural

84,000 (24.6)

0.166” (4.22 mm)

3.5

 

 

 

 

LP

66,000 (19.3)

0.116” (2.95 mm)

2.0

 

 

 

 

LP

84,000 (24.6)

0.100” (2.54 mm)

3.5

 

 

 

 

NOTE: The BTU input valves in the above table show the approximate hourly input of the burner for the various drill sizes shown. To determine the actual input of the burner, turn off all other gas appliances.

32

Unitary Products Group

Page 32
Image 32
York DFAH, DFAA Sizing Furnace Input, UIM-B-1105, Natural Gas, Propane Gas, Firing Rate, Orifice, Air Shutter