Temperature: -40° to +158° F (-40° to +70° C)

Relative humidity: 20% to 85% non-condensing

Should it become necessary to ship your printer, remove any ribbon and paper roll from the supply spools, otherwise damage to the printer could result. Carefully pack the printer in a suitable container to avoid damage during transit. Whenever possible, use the original container and packaging material from the factory. If you use a different con- tainer, a procedure similar to the original factory packaging should be followed.

CAUTION: Do not package the printer in a rigid container without utilizing shock mounts or shock-absorbing packing material. A rigid container will allow shock on the outside to be transmitted undamped to the unit, which may cause damage.

Power Connection

AC Voltage Selection Procedure

The S-Series Printer’s AC voltage may be set for either 115 VAC or

230 VAC operation. To match the printer’s power entry selection to the available power source, refer to Figure 2.1 and follow the procedure outlined below:

1.Locate the AC power area at the rear of the printer.

2.Using a small flatblade

screwdriver or similar tool, move the Voltage Selection switch to the 115 V or 230 V position as required. (The initial position of the switch depends on how the printer was ordered.) Make sure that the appropriate fuse is in place. See Figure 2.1.

Figure 2.1 AC Power Area

2-2