AC Power Fuse Replacement

A user-replaceable AC Power Fuse is located just above the Power ON/OFF Switch (see Figure 2.1). For a 115 VAC installation, the replacement fuse is a 3AG Fast Blow style rated at 5 Amp/250VAC. For a 230 VAC installation, the fuse is the same style but rated at 3 Amp/250 VAC. Make sure the fuse you use is correct for the voltage source.

Before replacing the fuse, turn the AC Power Switch OFF and unplug the AC Power Cable.

To replace the fuse, insert the tip of a flatblade screwdriver into the slot in the end of the Fuse Holder End Cap. Press in slightly on the End Cap and turn the screwdriver slightly counterclockwise. This will disengage the End Cap from the Fuse Holder and allow you to remove the fuse. To install a new fuse, reverse the procedure.

115 VAC Operation

1.Confirm that the voltage selector switch is set to 115 V.

2.Attach the supplied power cord to the AC power receptacle located on the rear of the printer.

3.Connect the opposite end of the power cord to a properly grounded source of 115 VAC (50 or 60 Hz) power rated for at least 5 Amps.

230 VAC Operation

1.Confirm that the voltage selector switch is set to 230 V.

2.Depending on how the printer was ordered, a power cord may or may not be provided for 230 VAC operation. If not provided, obtain a cord set with the proper AC Power plug. The cord may then be connected to the standard (international) IEC-type 3-prong AC connector provided on the S-Series Printer. Refer to “Appendix A” for more information.

Zebra S-Series User’s Guide

2-3