AC Power Fuse Replacement
A
Before replacing the fuse, turn the AC Power Switch OFF and unplug the AC Power Cable.
To replace the fuse, insert the tip of a flatblade screwdriver into the slot in the end of the Fuse Holder End Cap. Press in slightly on the End Cap and turn the screwdriver slightly counterclockwise. This will disengage the End Cap from the Fuse Holder and allow you to remove the fuse. To install a new fuse, reverse the procedure.
115 VAC Operation
1.Confirm that the voltage selector switch is set to 115 V.
2.Attach the supplied power cord to the AC power receptacle located on the rear of the printer.
3.Connect the opposite end of the power cord to a properly grounded source of 115 VAC (50 or 60 Hz) power rated for at least 5 Amps.
230 VAC Operation
1.Confirm that the voltage selector switch is set to 230 V.
2.Depending on how the printer was ordered, a power cord may or may not be provided for 230 VAC operation. If not provided, obtain a cord set with the proper AC Power plug. The cord may then be connected to the standard (international)
Zebra |