Note: If only one pair of lights is flickering, it indicates that the adjustment was not successful. Go back to step 1 and start over.

8.Open the printhead.

9.Pull the media out of the printer until a label is positioned under the printhead. Move the ribbon back to its normal position.

Note: Be sure that label is positioned between the upper and lower Media Sensors.

10.Close the printhead.

11.Press the MODE key to print a Media and Sensor Profile and save the new values (see Figure 7.4.).

12.Perform the Media Calibration procedure in “Configuration and Cali- bration.”

Figure 7.4 Media Sensor Profile Sample Printout

7-6

Zebra S-Series User’s Guide