RFID Guidelines ^RS
Parameters | Details | ||
e | = error handling | If an error persists after the specified number of labels are tried, perform this | |
|
| error handling action. | |
|
| Accepted values: | |
|
| • N = No action (printer drops the label format causing the error and moves to | |
|
|
| the next queued label) |
|
| • P = Place printer in Pause mode (label format stays in the queue until the | |
|
|
| user cancels) |
|
| • E = Place printer in Error mode (label format stays in the queue until the | |
|
|
| user cancels) |
|
| Default value: N | |
|
|
| Note • You can set the printer to send an error message to the host as an |
|
|
| unsolicited message for each failure. To enable or disable the |
|
|
| unsolicited error message, refer to the ^SX and ^SQ ZPL commands. |
|
|
| The parameter for the RFID error in these commands is V. |
a | = signals on applicator | When the value for parameter p (read/write position of the transponder) is | |
|
| nonzero, this parameter changes the number of start and stop print signals | |
|
| required for printing. | |
|
| In Single mode, one start print command is required. In Double mode, two are | |
|
| required, so the printer will resume printing only after the second start print | |
|
| command is received. | |
|
| Accepted values: | |
|
| • | S (single) signal |
|
| • | D (double) signal |
|
| Default value: S |
c= certify tag with a * Not used in this version of the printer. The encoder does this automatically.
s = void print speed | If a label is voided, the speed at which “VOID” will be printed across the label. |
| Accepted values: any valid print speed |
| Default value: the printer’s maximum print speed |
88 | R110Xi/R170Xi User Guide | 12/6/04 |