RFID Guidelines ^RS

Parameters

Details

e

= error handling

If an error persists after the specified number of labels are tried, perform this

 

 

error handling action.

 

 

Accepted values:

 

 

N = No action (printer drops the label format causing the error and moves to

 

 

 

the next queued label)

 

 

P = Place printer in Pause mode (label format stays in the queue until the

 

 

 

user cancels)

 

 

E = Place printer in Error mode (label format stays in the queue until the

 

 

 

user cancels)

 

 

Default value: N

 

 

 

Note • You can set the printer to send an error message to the host as an

 

 

 

unsolicited message for each failure. To enable or disable the

 

 

 

unsolicited error message, refer to the ^SX and ^SQ ZPL commands.

 

 

 

The parameter for the RFID error in these commands is V.

a

= signals on applicator

When the value for parameter p (read/write position of the transponder) is

 

 

nonzero, this parameter changes the number of start and stop print signals

 

 

required for printing.

 

 

In Single mode, one start print command is required. In Double mode, two are

 

 

required, so the printer will resume printing only after the second start print

 

 

command is received.

 

 

Accepted values:

 

 

S (single) signal

 

 

D (double) signal

 

 

Default value: S

c= certify tag with a * Not used in this version of the printer. The encoder does this automatically. pre-read*

s = void print speed

If a label is voided, the speed at which “VOID” will be printed across the label.

 

Accepted values: any valid print speed

 

Default value: the printer’s maximum print speed

88

R110Xi/R170Xi User Guide

12/6/04 23063L-003 Rev. 1