Front Panel Controls

Front Panel LCD

 

Table 7 • Standard LCD Displays (Page 11 of 16)

 

 

Parameter

Action/Explanation

 

 

MEDIA POWER UP

Media Power Up

 

This parameter sets the action of the labels when the printer is turned on.

 

• Press the right or left oval to display the choices.

 

Note • For best results with RFID labels, set this parameter to FEED or

 

LENGTH.

 

Default: CALIBRATION

 

Selections:

 

FEED—feeds the labels to the first registration point.

 

CALIBRATION—determines the length of the label and adjusts the sensor

 

settings.

 

LENGTH—In continuous mode, feeds the last stored label length. In

 

non-continuous mode, calibrates based on the maximum label length setting

 

(see Setting Maximum Length on page 46).

 

SHORT CAL—calibrates label length using the current sensor settings.

 

NO MOTION—the media does not move. You must press FEED to cause

 

the printer to resynch to the start of the next label.

 

 

HEAD CLOSE

Head Close

 

This parameter sets the action of the labels when the printhead is closed.

 

• Press the right or left oval to display the choices.

 

Note • For best results with RFID labels, set this parameter to FEED or

 

LENGTH.

Default: CALIBRATION

Selections:

FEED—feeds the labels to the first registration point.

CALIBRATION—determines the length of the label and adjusts the sensor settings.

LENGTH—In continuous mode, feeds the last stored label length. In non-continuous mode, calibrates based on the maximum label length setting (see Setting Maximum Length on page 46).

SHORT CAL—calibrates label length using the current sensor settings.

NO MOTION—the media does not move. You must press FEED to cause the printer to resynch to the start of the next label.

54

R110Xi/R170Xi User Guide

23063L-003 Rev. 1 12/6/04