Troubleshooting
LCD Error Messages
LCD Error MessagesThe LCD displays messages when there is an error. See Table 14 for LCD errors, the possible causes, and the recommended solutions.
Table 14 • LCD Error Messages
LCD | Possible Cause | Recommended Solution |
|
|
|
RIBBON OUT | Thermal Transfer Mode— | Load the ribbon correctly, following directions in |
| Ribbon is not loaded or is | |
| loaded incorrectly. |
|
|
|
|
| Thermal Transfer Mode— | Adjust the media and ribbon sensors. See |
| Ribbon is loaded but the ribbon | |
| sensor is not sensing the ribbon. |
|
|
|
|
| Direct Thermal Mode— | Make sure that ribbon is not loaded and that the |
| Ribbon is loaded. | printer is in Direct Thermal Print Mode. See |
|
| |
|
|
|
| Direct Thermal Mode— | Make sure the printer driver and software settings |
| Settings are incorrect. | are compatible with Direct Thermal Print Mode. |
|
|
|
PAPER OUT | Labels are not loaded or are | Load the labels correctly. See Loading the Media |
| loaded incorrectly. | |
|
|
|
| Media Sensor is not adjusted | Check the position of the media sensors, and adjust |
| correctly. | if necessary. See Calibrate Media and Ribbon |
|
| |
|
|
|
| Printer is set for | • Make sure the labels and the Media Type |
| labels but continuous labels are | settings match. See Setting Media Type |
| loaded. | |
|
| • Make sure the printer driver or software settings |
|
| match the label and Media Type settings. |
|
| • Calibrate the printer. For more information, see |
|
| |
|
|
|
| The MAX LENGTH setting is | Change the MAX LENGTH setting to a value that |
| set to a value that is shorter than | is at least 1 in. (25 mm) longer than the labels. |
| the actual length of the label. |
|
|
|
|
HEAD OPEN | The printhead is not fully | Close the printhead. |
| closed. |
|
|
|
|
HEAD ELEMENT | One or more of the printhead | • If the failed elements affect your printing |
BAD | elements failed the printhead | application, replace the printhead. |
| element test. | • To override this error, disable the head test count |
|
| feature on the front panel by defaulting the value |
|
| to 0000. |
|
|
|
R110Xi/R170Xi User Guide | 127 |