Front Panel Controls

Front Panel LCD

 

Table 7 • Standard LCD Displays (Page 15 of 16)

 

 

Parameter

Action/Explanation

 

 

RESYNCH MODE

Resynch Mode

 

This parameter determines how the printer reacts if the label synchronization is lost

 

and the label top is not where expected.

 

Feed Mode—If the label top is not where expected, the printer feeds a blank

 

label to find the label top position.

 

Error Mode—If the label top is not where expected, the printer stops, enters

 

Pause Mode, displays the message Error Condition Feed Label,

 

flashes the ERROR light, and asserts the Service Required signal (pin 10 on

 

the Applicator Interface Connector).

 

To resynch the media to the top of the label in Error Mode, press PAUSE to exit

 

Pause Mode. The ERROR light stops flashing, and the Service Required signal

 

is deactivated. The action of the printer is determined by the Head Close

 

configuration selection (see Head Close on page 54).

 

• Press the right or left oval to toggle between choices.

 

Default: FEED MODE

 

Selections: FEED MODE, ERROR MODE

 

 

WEB S.

These parameters are automatically set during the calibration procedure. They

 

should be changed only by a qualified service technician. See the Maintenance

MEDIA S.

Manual for more information on these parameters.

 

RIBBON S.

• Press NEXT/SAVE to scroll through these parameters.

 

 

TAKE LABEL

 

 

 

MARK S.

 

 

 

MARK MED S.

 

 

 

MEDIA LED

 

 

 

RIBBON LED

 

 

 

MARK LED

 

 

 

LCD ADJUST

Adjust LCD Contrast

 

This parameter allows you to adjust the contrast of your LCD if it is difficult to

 

read.

 

1. Press the left oval to move the cursor.

 

2. Press the right oval to toggle +/- or to increase the value of the digit.

 

Range: 00 to 19

 

 

FORMAT CONVERT

Select Format Conversion Factor

 

Selects the bitmap scaling factor. The first number is the original dots per inch (dpi)

 

value; the second, the dpi to which you would like to scale.

 

Note • Not applicable on all printers.

 

• Press the right or left oval to display other choices.

 

Default: None

 

Selections: None, 150 → 300, 150 → 600, 200 → 600, 300 → 600

 

 

58

R110Xi/R170Xi User Guide

23063L-003 Rev. 1 12/6/04