RFID Guidelines

^WT

Parameters Details

f = data format

Accepted values:

 

0

(ASCII)

 

1

(Hexadecimal)

 

Default value: 0

v = verify valid data Used only for Alien Class 1 tags, which have preprogrammed data in them. This parameter flags whether the preprogrammed data is verified. (Same function as the ^WV command)

Default value: N

Accepted values:

N (Do not verify)

Y (Verify valid data [Hex A5A5 in the first two bytes] before writing)

Example • This sample encodes data “RFIDRFID” and will try writing up to five times, if necessary.

^XA

^WT,5^FDRFIDRFID^FS

^XZ

96

R110Xi/R170Xi User Guide

12/6/04 23063L-003 Rev. 1