Color profile: Disabled
Composite Default screen
2.Locate the Upper Media Sensor. Refer to Figure 4. The Upper Media Sensor is directly below the adjustment screw head.
3.Loosen the Upper Media Sensor Adjustment screw (Phillips head).
4.Slide the upper sensor along the slot to the desired position. When using label stock that has a gap between labels
5.Tighten the screw.
LOWER
MEDIA SENSOR
Figure 5. Lower Media Sensor AdjustmentLower Media Sensor AdjustmentRefer to Figure 5 throughout this procedure.
1.Locate the Lower Media Sensor assembly (a spring clip holding a circuit board) near the bottom rear of the printhead assembly.
2.Position the sensor by sliding it in its slot so that the two
Zebra | 17 |
29
H:...Xi2UsersGuideR2.vp
Fri Aug 07 10:34:45 1998