Color profile: Disabled

Composite Default screen

2.Locate the Upper Media Sensor. Refer to Figure 4. The Upper Media Sensor is directly below the adjustment screw head.

3.Loosen the Upper Media Sensor Adjustment screw (Phillips head).

4.Slide the upper sensor along the slot to the desired position. When using label stock that has a gap between labels (die-cut label stock), position the media sensor anywhere along the gap EXCEPT where the rounded corners of the label are detected. When using tagstock, position the up- per sensor directly over the hole or notch.

5.Tighten the screw.

LOWER

MEDIA SENSOR

Figure 5. Lower Media Sensor AdjustmentLower Media Sensor Adjustment

Refer to Figure 5 throughout this procedure.

1.Locate the Lower Media Sensor assembly (a spring clip holding a circuit board) near the bottom rear of the printhead assembly.

2.Position the sensor by sliding it in its slot so that the two brass-colored infrared emitters are centered under the upper sensor.

Zebra XiII-Series User’s Guide

17

29

H:...Xi2UsersGuideR2.vp

Fri Aug 07 10:34:45 1998