Color profile: Disabled

Composite Default screen

Cleaning the Cutter Module

(For printers equipped with the optional cutter.)

The Cutter Module requires periodic cleaning to remove paper dust and gummed label residue. The procedure should be performed by the operator as needed to ensure proper cutter action. If labels are not being cut properly, or if the cutter jams with labels, this is an indication that the cutter probably needs cleaning. The cleaning frequency depends on your application and media type.

Clean the stationary cutter blade with cleaning solvent when it becomes gummed up with label adhesive and/or paper debris. If further cutter cleaning is necessary, or if the cutter performs unsatisfactorily, contact a service technician.

Lubrication

CAUTION! No lubricating agents of any kind should be used on this printer! Some commercially available lubricants will damage the finish and the mechanical parts if used.

Fuse Replacement

The Zebra XiII printer uses a metric-style fuse (5 X 20 mm IEC) rated at F5A, 250V. The end caps of the fuse must bear the certification mark of a known international safety organization (See Figure 20, “International Safety Organizations,” on page 82). The printer comes with two approved fuses: one in the circuit and one in the “spare fuse” holder.

1.Turn the printer power off and unplug the power cord from the back of the printer. See Figure 12.

2.Using a small-blade screwdriver or similar tool, remove the Fuse Holder from the printer.

54

Zebra XiII-Series User’s Guide

66

H:...Xi2UsersGuideR2.vp

Fri Aug 07 10:36:17 1998