Prestige 623ME-T User’s Guide

19.4 SNMP Traps

The Prestige will send traps to the SNMP manager when any one of the following events occurs:

Table 19-2 SNMP Traps

TRAP #

TRAP NAME

DESCRIPTION

 

 

 

1

coldStart (defined in RFC-1215)

A trap is sent after booting (power on).

 

 

 

2

warmStart (defined in RFC-1215)

A trap is sent after booting (software reboot).

 

 

 

3

linkDown (defined in RFC-1215)

A trap is sent when the port is down.

 

 

 

4

linkUp (defined in RFC-1215)

A trap is sent when the port is up.

 

 

 

5

authenticationFailure (defined in

A trap is sent to the manager when receiving any SNMP

 

RFC-1215)

get or set requirements with wrong community (password).

 

 

 

6

whyReboot (defined in ZYXEL-

A trap is sent with the reason of restart before rebooting

 

MIB)

when the system is going to restart (warm start).

 

 

 

6a

For intentional reboot :

A trap is sent with the message "System reboot by user!" if

 

 

reboot is done intentionally, (for example, download new

 

 

files, CI command "sys reboot", etc.).

 

 

 

The following table maps the physical port and encapsulation to the interface type.

Table 19-3 Ports and Interface Types

PHYSICAL PORT/ENCAP

INTERFACE TYPE

 

 

LAN port(s)

enet0

 

 

Wireless port

enet1

 

 

PPPoE encap

pppoe

 

 

1483 encap

mpoa

 

 

Ethernet encap

enet-encap

 

 

PPPoA

ppp

 

 

19-4

SNMP Configuration