MAINTENANCE
IMPORTANT INFORMATION
The blades on a BioClip unit should be set at 90 degrees to each other. In all other cases the blades can collide and cause serious damage to the cutting unit.
5. Ensure the blades are positioned as set out in the diagram, at 90 degrees to each other, otherwise the belt must be adjusted. When the blade bearings are loose the belt can be moved around to the next tooth.
Tighten the nuts enough so that the bearings rest against the cutting hood but still can be moved.
Tension the belt by turning the eccentric adjuster on top of the cutting hood. Tighten the nut.
Tighten all nuts on the blade bearings.
6. When the belt can be moved 8 mm (5/16") inwards using a force of 7 N (1.5 lb) the belt is adjusted correctly.
7.Fit the protective cover over the belts and replace the parall strut.
Belt change on Combi 103
1. Remove the cutting unit.
2. Remove the front bolt from the parallel strut and tip the strut backwards. Push the height adjustment strut forwards.
WARNING!
Wear gloves to protect your hands when working with the blades.
3. Loosen the two bolts holding the protective hood and then lift off the hood.
32 – English