Table A-3.Rosemount 644 Smart Temperature Transmitter Ordering Information

The Standard offering represents the most common models and options. These options should be selected for best delivery. The Expanded offering is manufactured after receipt of order and is subject to additional delivery lead time.

= Available

 

 

 

 

 

 

 

– = Not Available

 

 

Cable Gland Option

 

 

 

 

 

 

 

 

 

 

Standard

 

 

 

 

 

 

 

 

 

 

Standard

G2

 

Cable gland(6) (7.5 mm - 11.99 mm)

 

 

 

G7

 

Cable gland, M20x1.5, Ex e, Blue Polyamide (5 mm - 9 mm)

 

Cover Chain Option

 

 

 

 

 

 

 

 

 

 

Standard

 

 

 

 

 

 

 

 

 

 

Standard

G3

 

Cover chain

 

 

 

 

 

Terminal

 

 

 

 

 

 

 

 

 

 

 

 

Standard

 

 

 

 

 

 

 

 

 

 

Standard

G5

 

WAGO spring clamp terminals

 

 

 

 

 

Conduit

Electrical Connector

 

 

 

 

 

 

 

 

 

 

Standard

 

 

 

 

 

 

 

 

 

 

Standard

GE(7)

 

M12, 4-pin, Male Connector (eurofast®)

 

 

GM(7)

 

A size Mini, 4-pin, Male Connector (minifast®)

 

External

Label

 

 

 

 

 

 

 

 

 

 

Standard

 

 

 

 

 

 

 

 

 

 

Standard

EL

 

External label for ATEX Intrinsic Safety

 

 

Typical Rail Mount Model Number:

644

R

A

I5

 

 

 

 

 

 

Typical Head Mount Model Number:

644

H

F

I5 M5 J5 C1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)Requires enclosure option J5, J6, J7, or J8.

(2)When IS approval is ordered on a FOUNDATION fieldbus, both standard IS and FISCO IS approvals apply. The device label is marked appropriately.

(3)Consult factory for availability.

(4)Suitable for remote mount configuration.

(5)When ordered with XA, 1/2-in. NPT enclosure will come equipped with an M20 adapter with the sensor installed as process ready.

(6)Only available with Enclosure option code J5.

(7)Available with Intrinsically Safe approvals only. For FM Intrinsically Safe or non-incendive approval (option code I5), install in accordance with Rosemount drawing 03151-1009 to maintain NEMA 4X rating.

NOTE

For additional options (e.g. “K” codes), please contact your local Emerson Process Management representative.

Tagging

Hardware

13 characters total

Tags are adhesive labels

Permanently attached to transmitter

Character height is 1/16-in (1.6 mm)

Software

The transmitter can store up to 13 characters for FOUNDATION fieldbus and Profibus PA. If no characters are specified, the first 8 characters of the hardware tag are the default.

Considerations

Special Mounting Considerations

See “Mounting” on page A-10for the special hardware that is available to:

Mount a 644H to a DIN rail. (see Table 1 on page A-15)

Retrofit a new 644H to replace an existing 644H transmitter in an existing threaded sensor connection head (see Table 1 on page A-15).

A-14

Image 60
Contents Reference Manual 00809-0400-4728, Rev AA JunePage Table of Contents Specifications Reference Data Appendix aAppendix B TOC-2Rosemount Temperature Transmitters Customer Central National Response Center InternationalPage Safety Messages Section IntroductionExplosions could result in death or serious injury Process leaks could result in death or serious injuryOverview ManualTransmitter Considerations 22 20 815 C 1500 F Oven Temperature 250 C 482 F Oven Temperature 5 6 7 8 Extension LengthExample AboveSection Installation Within Specifications? Refer to Configuration Bench Calibration?Simulate Sensor Input From draining into the transmitter housing MountingMounting a 644H to a DIN Rail Rail asymmetricInstallation Typical European InstallationHead Mount Transmitter with DIN Plate Style Sensor Typical North American Installation Head Mount Transmitter with Threaded SensorLCD Display Installation Installing the LCD DisplayWiring Power terminals does not drop below 9 VdcSensor Connections Thermocouple or Millivolt InputsSensor Lead Wire Resistance Effect- RTD Input Sensor Input Approximate Basic ErrorRTD or Ohm Inputs Pt100 2-wire RTD Error due to amb. temp. var. of ± 25 CPower Supply Foundation fieldbus InstallationGround the Transmitter Ungrounded Thermocouple, mV, and RTD/Ohm InputsGrounded Thermocouple Inputs Section Configuration Overview Safety MessagesGeneral Block Information Device Description Node AddressModes AutoLink Active Scheduler Block Installation Resource Transducer Analog Input OtherCapabilities Foundation Fieldbus Function BlocksFeatures Resource BlockUnicode ReportsFeaturessel FailedalarmsMaxnotify PlantWeb AlertsMaintalarms FailedmaskAdvisory Alarms Recommended Actions for PlantWeb AlertsRecommendedaction Configure the AI block Sensor Transducer BlockAnalog Input AI Function Block DampingPressure Channel Temperature Channel LtypeXdscale and Outscale Configuration Examples Transducer BlockProcess Alarms FilteringAlarmtype OutdLCD Transducer Block DisplayparamselBLKTYPE#1 PARAMINDEX#1Operation and Maintenance OverviewUNITSTYPE#1 CUSTOMUNITS#1Troubleshooting Guides Troubleshooting guideProblems with communications flowchart Calpointlo + Calminspan Diagnostics Recall Factory TrimBlock Blockerr messages Sensor Transducer Block Xderr messagesDescription CalibrationerrManual Mode StatusSimulation SimulateTroubleshooting AI block Power UpSymptom Possible Causes Recommended Actions 00809-0400-4728, Rev AA June AI Blockerr ConditionsBlock Errors 8lists conditions reported in the Blockerr parameter10. Resource Block Condition NameSelf Test Procedure for the LCD Symptom Possible Causes Recommended ActionAuto Appendix a Specifications Reference Data SpecificationsFunctionalInputs Physical Performance Foundation Fieldbus Specifications Rosemount Conformance to SpecificationsFunction Blocks 2 σ -1 σPower Supply AlarmsBackup Link Active Scheduler LAS Software Upgrade in the FieldAccuracy Table A-1. Rosemount 644 Input Options and AccuracyAccuracy Example Ambient Temperature Effect Table A-2. Ambient Temperature EffectThermocouples Temperature Effects Examples Dimensional Drawings 644H DIN a Head MountLCD Display Mounting00809-0400-4728, Rev AA JuneSanitary Housing Covers LCD Display CoverRing 76.2 27.9 74.4 25.4 44.5 70.0 Ordering Information OptionsConfiguration Standard Alarm Level Configuration StandardAssemble To Options Standard Enclosure Options StandardTagging ConsiderationsTransmitter Configuration Configuration toolWith DeltaV, with AMS, or other Foundation fieldbus host or Standard Foundation fieldbus Configuration Custom ConfigurationRequirements Option Code Specification Standard Block ConfigurationCE Electromagnetic Compatibility Compliance Testing Appendix B Product CertificationsAtex Directive 94/9/EC Hazardous Locations Certificates North American CertificationsRosemount 644 with Foundation fieldbus Loop/Power Terminals Fisco Loop/Power TerminalsEuropean Certifications Special Conditions for Safe UseTemperature Class IECEx CertificationsTo 60 C Fisco Group IIC To 80 CTable B-3. Entity Parameters Transmitter I.S Transmitter Fisco SensorTransmitter Sensor Schedule of LimitationsUkraine Gost Pattern Approval for Measuring Instruments See CertificateApproval Temp Description Group CodeInstallation Drawings Rosemount Rosemount Rosemount 00809-0100-4728, Rev AA June Sheet 2 00809-0100-4728, Rev AA June Sheet 3 00809-0100-4728, Rev AA June 00809-0100-4728, Rev AA June Sheet 2 Rosemount Rosemount 00809-0100-4728, Rev AA June Sheet 2 00809-0100-4728, Rev AA June Sheet 3 Basic Setup Resource Block Appendix C Foundation fieldbus Block InformationDefinition Parameters and Descriptions IndexFailedenable FeaturesFeaturesel Maintenable00809-0400-4728, Rev AA Sensor Transducer Block Parameters DescriptionsDescription Effects transmitter operation Primaryvaluerange PrimaryvaluetypeSensrdetailedstatus CalvandusencoeffXderror SESNOR1DAMPINGTransducerdirectory TransducertypeAnalog Measurement Access Analog Input AI Function BlockOutd Cutoff Filter Convert CalcAI Parameter Table AckoptionLolopri LCD Transducer Block Table C-4. LCD Transducer Block Parameters and DescriptionsParameter Index Description PID Block Table C-5. PID Block Parameters and DescriptionsParameter Index Index Ungrounded Wiring MODEBLK.TARGET Bad UncertainLolim Lololim Lolopri Lopri Lower Trim Method DIN Rail Threaded SensorLimited Man Mode Unicode UNITSTYPE# Upper Trim Method Grounded Ungrounded WiringSecurity Self Test Direct Zero TrimIndex-4 Page Temperature GmbH Pacific Private Limited Emerson Process Management Rosemount Inc