Emerson 644 manual Transmitter Configuration, Configuration tool

Page 61

Reference Manual

00809-0400-4728, Rev AA June 2011

Rosemount 644

External Ground Screw Assembly

The external ground screw assembly can be ordered by specifying code G1 when an enclosure is specified. However, some approvals include the ground screw assembly in the transmitter

shipment, hence it is not necessary to order code G1. The table below identifies which approval options include the external ground screw assembly and which do not.

 

External Ground Screw

Approval Type

Assembly Included?

E5, I1, I2, I5, I6, I7, K5,

No–Order option code G1

K6, NA, I4

 

E1, E2, E3, E4, E7, K7,

Yes

N1, N7, ND

 

TABLE 1. Transmitter Accessories

Part Description

Part Number

Aluminum alloy Universal Head, standard cover—M20 entries

00644-4420-0002

Aluminum alloy Universal Head, meter cover—M20 entries

00644-4420-0102

Aluminum alloy Universal Head, standard cover—1/2-14 NPT entries

00644-4420-0001

Aluminum alloy Universal Head, meter cover—1/2-14 NPT entries

00644-4420-0101

LCD Display (includes meter and meter spacer assembly)

00644-4430-0002

LCD Display kit (includes meter and meter spacer assembly, and meter cover)

00644-4430-0001

Ground screw assembly kit

00644-4431-0001

Kit, Hardware for mounting a 644H to a DIN rail (includes clips for symmetrical and asymmetrical rails)

00644-5301-0010

Kit, Hardware for retrofitting a 644H in an existing threaded sensor connection head (former option code L1)

00644-5321-0010

Kit, 316 U-Bolt for Universal Housing

00644-4423-0001

Universal clip for rail or wall mount

03044-4103-0001

24 Inches of symmetric (top hat) rail

03044-4200-0001

24 Inches of asymmetric (G) Rail

03044-4201-0001

Ground clamp for symmetric or asymmetric rail

03044-4202-0001

End clamp for symmetric or asymmetric rail

03044-4203-0001

Snap rings kit (used for assembly to a DIN sensor – quantity 12)

00644-4432-0001

SST Universal Head, standard cover—M20 entries

00644-4433-0002

SST Universal Head, meter cover—M20 entries

00644-4433-0102

SST Universal Head, standard cover—1/2-14 NPT entries

00644-4433-0001

SST Universal Head, meter cover—1/2-14 NPT entries

00644-4433-0101

Polished SST Connection Head, standard cover—1/2-14 NPT entries

00079-0312-0011

Polished SST Connection Head, meter cover—1/2-14 NPT entries

00079-0312-0111

Polished SST Connection Head, standard cover—1/2-14 NPSM entries

00079-0312-0022

Polished SST Connection Head, meter cover—1/2-14 NPSM entries

00079-0312-0122

Polished SST Connection Head, standard cover—M20 x 1.5 entries

00079-0312-0033

Polished SST Connection Head, meter cover—M20 x 1.5 entries

00079-0312-0133

Polished SST Connection Head, standard cover—M20 x 1.5 / M24 x 1.5 entries

00079-0312-0034

Polished SST Connection Head, meter cover—M20 x 1.5 / M24 x 1.5 entries

00079-0312-0134

Configuration

Transmitter Configuration

 

The transmitter is available with standard configuration setting for

 

FOUNDATION fieldbus (see “Custom configurations are to be specified when

 

ordering. This configuration must be the same for all sensors. The following

 

table lists the necessary requirements to specify a custom configuration.”).

 

The configuration settings and block configuration may be changed in the field

 

with DeltaV®, with AMS, or other FOUNDATION fieldbus host or

 

configuration tool.

A-15

Image 61
Contents 00809-0400-4728, Rev AA June Reference ManualPage Table of Contents Appendix a Specifications Reference DataAppendix B TOC-2Customer Central National Response Center International Rosemount Temperature TransmittersPage Section Introduction Safety MessagesExplosions could result in death or serious injury Process leaks could result in death or serious injuryManual OverviewTransmitter Considerations 250 C 482 F Oven Temperature 5 6 7 8 Extension Length 22 20 815 C 1500 F Oven TemperatureExample AboveSection Installation Bench Calibration? Within Specifications? Refer to ConfigurationSimulate Sensor Input Mounting From draining into the transmitter housingMounting a 644H to a DIN Rail Rail asymmetricTypical European Installation InstallationHead Mount Transmitter with DIN Plate Style Sensor Head Mount Transmitter with Threaded Sensor Typical North American InstallationInstalling the LCD Display LCD Display InstallationPower terminals does not drop below 9 Vdc WiringThermocouple or Millivolt Inputs Sensor ConnectionsSensor Input Approximate Basic Error Sensor Lead Wire Resistance Effect- RTD InputRTD or Ohm Inputs Error due to amb. temp. var. of ± 25 C Pt100 2-wire RTDFoundation fieldbus Installation Power SupplyGround the Transmitter Ungrounded Thermocouple, mV, and RTD/Ohm InputsGrounded Thermocouple Inputs Overview Safety Messages Section ConfigurationDevice Description Node Address General Block InformationModes AutoResource Transducer Analog Input Other Link Active Scheduler Block InstallationFoundation Fieldbus Function Blocks CapabilitiesResource Block FeaturesUnicode ReportsFailedalarms FeaturesselMaxnotify PlantWeb AlertsFailedmask MaintalarmsRecommended Actions for PlantWeb Alerts Advisory AlarmsRecommendedaction Sensor Transducer Block Configure the AI blockAnalog Input AI Function Block DampingLtype Pressure Channel Temperature ChannelXdscale and Outscale Transducer Block Configuration ExamplesFiltering Process AlarmsOutd AlarmtypeDisplayparamsel LCD Transducer BlockBLKTYPE#1 PARAMINDEX#1Overview Operation and MaintenanceUNITSTYPE#1 CUSTOMUNITS#1Troubleshooting guide Troubleshooting GuidesProblems with communications flowchart Calpointlo + Calminspan Recall Factory Trim DiagnosticsBlock Blockerr messages Sensor Transducer Block Xderr messagesCalibrationerr DescriptionStatus Manual ModeSimulation SimulatePower Up Troubleshooting AI blockSymptom Possible Causes Recommended Actions 00809-0400-4728, Rev AA June AI Blockerr Conditions8lists conditions reported in the Blockerr parameter Block Errors10. Resource Block Condition NameSymptom Possible Causes Recommended Action Self Test Procedure for the LCDAuto Specifications Appendix a Specifications Reference DataFunctionalInputs Physical Performance Rosemount Conformance to Specifications Foundation Fieldbus SpecificationsFunction Blocks 2 σ -1 σAlarms Power SupplyBackup Link Active Scheduler LAS Software Upgrade in the FieldTable A-1. Rosemount 644 Input Options and Accuracy AccuracyAccuracy Example Table A-2. Ambient Temperature Effect Ambient Temperature EffectThermocouples Temperature Effects Examples 644H DIN a Head Mount Dimensional DrawingsMounting LCD Display00809-0400-4728, Rev AA JuneLCD Display Cover Sanitary Housing CoversRing 76.2 27.9 74.4 25.4 44.5 70.0 Options Ordering InformationAlarm Level Configuration Standard Configuration StandardAssemble To Options Standard Enclosure Options StandardConsiderations TaggingConfiguration tool Transmitter ConfigurationWith DeltaV, with AMS, or other Foundation fieldbus host or Custom Configuration Standard Foundation fieldbus ConfigurationRequirements Option Code Specification Standard Block ConfigurationAppendix B Product Certifications CE Electromagnetic Compatibility Compliance TestingAtex Directive 94/9/EC North American Certifications Hazardous Locations CertificatesRosemount 644 with Foundation fieldbus Fisco Loop/Power Terminals Loop/Power TerminalsEuropean Certifications Special Conditions for Safe UseIECEx Certifications Temperature ClassTo 60 C Fisco Group IIC To 80 CTransmitter I.S Transmitter Fisco Sensor Table B-3. Entity ParametersTransmitter Sensor Schedule of LimitationsPattern Approval for Measuring Instruments See Certificate Ukraine GostApproval Temp Description Group CodeInstallation Drawings Rosemount Rosemount Rosemount 00809-0100-4728, Rev AA June Sheet 2 00809-0100-4728, Rev AA June Sheet 3 00809-0100-4728, Rev AA June 00809-0100-4728, Rev AA June Sheet 2 Rosemount Rosemount 00809-0100-4728, Rev AA June Sheet 2 00809-0100-4728, Rev AA June Sheet 3 Appendix C Foundation fieldbus Block Information Basic Setup Resource BlockDefinition Index Parameters and DescriptionsFeatures FailedenableFeaturesel Maintenable00809-0400-4728, Rev AA Parameters Descriptions Sensor Transducer BlockDescription Effects transmitter operation Primaryvaluetype PrimaryvaluerangeSensrdetailedstatus CalvandusencoeffSESNOR1DAMPING XderrorTransducerdirectory TransducertypeAnalog Input AI Function Block Analog Measurement AccessOutd Cutoff Filter Convert CalcAckoption AI Parameter TableLolopri Table C-4. LCD Transducer Block Parameters and Descriptions LCD Transducer BlockParameter Index Description Table C-5. PID Block Parameters and Descriptions PID BlockParameter Index Index Bad Uncertain Ungrounded Wiring MODEBLK.TARGETLolim Lololim Lolopri Lopri Lower Trim Method DIN Rail Threaded SensorGrounded Ungrounded Wiring Limited Man Mode Unicode UNITSTYPE# Upper Trim MethodSecurity Self Test Direct Zero TrimIndex-4 Page Emerson Process Management Rosemount Inc Temperature GmbH Pacific Private Limited