Husky HD1500 Operating Connections, High Pressure Hose, Extension Cords, Power Supply Connection

Page 13

English

4.0OPERATING CONNECTIONS

(See pages 9-11)

4.1HIGH PRESSURE HOSE

Remove and discard the water plug. (Fig.9)

Attach the high pressure hose by carefully inserting the fitting with the o-ring into the high pressure outlet and tighten the threaded nut by hand. (Fig.10)

4.2WATER CONNECTION (Cold water) Before connecting, run water through the garden hose (not supplied) to flush out any foreign matter. Attach garden hose to the pressure washer water inlet con- nection. (Fig. 11) Page 9.

If your water source is a Well, the garden hose length can only be 30 ft. (9m) max.

EXTENSION CORDS

Use only extension cords that are intended for outdoor use. These extension cords are identified by a marking “Acceptable for use with outdoor appliances: store indoors while not in use”. Use only extension cords having an electrical rating not less than the rating of the product. Do not use damaged extension cords.

Examine extension cord before using and replace if damaged.

Do not abuse extension cord and do not pull on any cord to disconnect.

Keep cord away from heat and sharp edges. Always disconnect the product from the extension cord.

When using an extension cord, observe the specifi- cation below:

Cable Length

Wire Gauge

Up to 25 ft.

12 AWG Outdoor

ATTENTION:

Proper water connection (Fig.11).

4.3POWER SUPPLY CONNECTION

The pressure washer is factory-equipped with an electrical cord and a ground fault circuit interrupter (GFCI) plug (Fig.14). This cord should only be connected to an electrical outlet installed in accordance with local safety regulations.

NOTE: The power supply must be 120V, 60hz and a minimum 15 amp dedicated circuit.

WARNING: Test GFCI before each use. DO NOT use pressure washer if

WARNING test below fails.

GFCI Test Procedures (Fig.14):

WARNING

WARNING

WARNING

WARNING: To reduce the risk of electrocution, keep all connections dry and off the ground. Do not touch plug with wet hands.

A. Inspect cord before using. Do not use if cord is damaged.

B. Keep all connections dry and off the ground.

C. Do not touch plug with wet hands.

WARNING: Do not pull on any cord to move unit from one location to another.

1.Plug GFCI into power receptacle. Indicator should turn red.

2.Press Test button. Red indicator should disap- pear.

3.Press Reset button for use. When released, red indicator will reappear.

Do not use if above test fails.

NOTE: The GFCI must be reset each time the pressure washer is connected to an electrical outlet. Reset by simply pushing the reset button on the GFCI power plug.

 

A. Connect only to properly grounded

 

outlet.

WARNING

B. Inspect cord before using. Do not use

if cord is damaged.

C.Keep all connections dry and off the ground.

D.Do not touch plug with wet hands.

E.The pressure washer is provided with a ground-fault circuit interrupter built into the power plug.

If replacement of the plug or cord is needed, use only identical replacement parts. Contact Customer Service at www.huskypowerwasher.com for proper replacement parts.

GROUND-FAULT CIRCUIT-INTERRUPTER PRO- TECTION

A.Connect to only a properly grounded GFCI circuit.

B.This pressure washer is provided with a ground- fault circuit-interrupter (GFCI) built into the plug of the power-supply cord. This device provides additional protection from the risk of electric shock. Should replacement of the plug or cord become necessary , use only identical replacement parts that include GFCI protection.

13

Image 13
Contents Operator’s Manual Manual del Usuario Manuel de l’opérateur Serial Number 200Mounting bracket is designed for use with HD 1500 Hsds only Moving and Storage InstructionsEnglish Store high pressure cleaner on the docking station as shown Assembly InstructionsParts Drawing Spray Gun Variable Nozzle with Lance Parts List FigIndex Connect the Garden Hose Remove the Water Plug Connect the High Pressure Hose1010 Connect to Water Supply Insert the Wand Into the Spray GUN1111 Turn on Water Supply Start the Pressure WasherGROUND-FAULT CIRCUIT-INTERRUPTER PRO- Tection Important Safety InstructionsAutomatic Total STOP→ Motor OverloadOperating Connections Power Supply ConnectionHigh Pressure Hose Extension CordsOperating Instructions START-UP ProcedureVariable Spray Nozzle English USE of Detergent Cleaning TechniquesApplication of Detergent Application of Liquid Vehicle WAXServicing a DOUBLE- Insulated Appliance MaintenanceProblem or Concern Possible Cause Solution TroubleshootingNever use Bleach, Ammonia or Hot Water in the unitUnit Water Water leaking anywhere from the Manifold Manifold Assembly is leakingPump housing is leaking water Ensure that there are no kinks in the HoseHuskypowerwasher.com Wand Attaching To attach the Wand apply some moderate @huskypowerwasher.comWand Removing Limited Warranty Technical Data10% Max Implied Warranties HOW to Obtain Warranty ServiceNúmero de Serie ImportanteInstrucciones Para Movilizar Y Almacenar EL Equipo Español Instrucciones DE Montaje Diseño Piezas Lista Piezas Fig Pag ÍndiceConecte LA Manguera DE Alta Presión Extraiga EL Tapón DEL AguaConecte LA Manguera Para JardínIntroduzca EL Tubo EN LA Pistola Rociadora Conecte CON EL Suministro DE AguaEspañolñol Guarde Estas Instrucciones Importantes Instrucciones DE SeguridadSobrecarga DEL Motor Atención Conexión apropiada del agua Conexiones OperativasEmpalme DE LA Alimentación Eléctrica ExtensionesProcedimiento DE Puesta EN Marcha Instrucciones DE USOBoquilla Chorro Regulable Español Técnicas DE Limpieza USO DEL DetergenteAplicación DEL Detergente Aplicación DE LA CeraManutención DE UN Equipo CON Doble Aislamiento MantenimientoPowerwasher.com Problema Causas Posibles SoluciónLocalización DE LAS Averías Niaco o agua caliente en la unidadNosotros encustomerservice@huskyp En customerservice@huskypowerwaSher.com Erservice@huskypowerwasher.com En una proporción igual a la de la manguera El tubo no funciona correctaDel jardín Conectar el tuboPresión bomba Psi 102,4 bar Datos TécnicosDel jabón 10% max Garantía limitadaCómo Obtener EL Servicio Garantía Date d’achat Instructions DE Deplacement ET Entreposage Français Instructions DE Montage Illustration DES Pièces Pièces Fig Contents Branchez LE Tuyau D’ARRO- Sage Pour UNE Installation SimpleBranchez AU Robinet Insérez LA Lance Dans LE Pistolet Français Conserver CES Instructions Instructions Importantes DE SecuriteSurcharge DU Moteur Protection PAR Disjoncteur DE Fuite À LA TerreBranchement DE L‘ALIMENTATION Électrique InstallationRallonges Mise EN Marche Mode D’EMPLOILance Avec Tête Réglable Français Techniques DE Nettoyage Utilisation DE DétergentsApplication DE Détergents Application DE Cire Liquide Pour VéhiculesEntretien D’UN Appareil a Double Isolation EntretienGuide DE Dépannage Probleme Cause Possible Solution’ensemble collecteur fuit Ouvert ou l’unité ne reçoit pas un Plein volume d’eauTie inférieure de l’unité Com pour une assistance techniqueRservice@huskypowerwasher.com Correctement Ne s’arrête pas lorsque laRosage Lance BranchementBar 6,82 bar Données TechniquesSi des pièces sont manquantes ou endomma Garantie limitéeFrançais 2005 cod. PLDCxxxxx REV